All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 45Systems 3,474Components 15,410Accessories 0

Showing 5,617–5,640 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland 6DUNR49ME-TSE (R22 Discus recip, 60 Hz, MD) CatalogCopelandR22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLJ083T4 (R410A scroll, 50 Hz) CatalogDanfossR410A compressor — 18.2 kW cooling, 6.27 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU6217U (R290 hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR290 compressor — 2.0 kW cooling, 1.01 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB4581ZTZ (R452A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR452A compressor — 16.3 kW cooling, 7.68 kW input, COP 2.12 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DUXF13ME-TSE (R407C Discus recip, 50 Hz, LD) CatalogCopelandR407C compressor — 23.4 kW cooling, 14.04 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRH034U2A (R454B scroll, 50 Hz) CatalogDanfossR454B compressor — 7.2 kW cooling, 2.69 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6220UV (R290 hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR290 compressor — 2.2 kW cooling, 0.93 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464P-TZ1A (R452A hermetic, LBP, EN12900, 50 Hz) CatalogTecumsehR452A compressor — 0.66 kW cooling, 0.71 kW input, COP 0.93 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DUXR49ME-TSE (R22 Discus recip, 60 Hz, MD) CatalogCopelandR22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM045U2 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 13.2 kW cooling, 4.01 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2X1121U (R290 hermetic, MBP, EN12900, 50-60 Hz) CatalogEmbracoR290 compressor — 0.21 kW cooling, 0.13 kW input, COP 1.69 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4522Z-XG1A (R452A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR452A compressor — 5.6 kW cooling, 2.31 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DVNF13ME-TSE (R407C Discus recip, 50 Hz, LD) CatalogCopelandR407C compressor — 23.4 kW cooling, 14.04 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRP054T1 (R407C scroll, 60 Hz, A/C) CatalogDanfossR407C compressor — 15.1 kW cooling, 4.76 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMT6144GK (R404A hermetic, MBP, EN12900, 50 Hz) CatalogEmbracoR404A compressor — 0.56 kW cooling, 0.28 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4440Y-GS1A (R134a hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR134a compressor — 1.1 kW cooling, 0.53 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DVNR49ME-TSE (R22 Discus recip, 60 Hz, MD) CatalogCopelandR22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ015T2A (R448A scroll, 60 Hz, LT) CatalogDanfossR448A compressor — 3.8 kW cooling, 2.85 kW input, COP 1.32 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EMX66CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogEmbracoR600a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4543N-TZ1A (R1234yf hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR1234yf compressor — 9.6 kW cooling, 4.59 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DVXF13ME-TSE (R407C Discus recip, 50 Hz, LD) CatalogCopelandR407C compressor — 23.4 kW cooling, 14.04 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ015T2C (R454C scroll, 60 Hz) CatalogDanfossR454C compressor — 6.1 kW cooling, 2.09 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY70HSC (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogEmbracoR134a compressor — 0.16 kW cooling, 0.11 kW input, COP 1.51 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AGB4581ZTZ (R452A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR452A compressor — 19.1 kW cooling, 9.71 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…233234235236237…602Next ›