| Name | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|
| Copeland 4YHNS14ME-TSK (R455A Discus recip, 60 Hz, MD) Catalog | Copeland | R455A compressor — 32.5 kW cooling, 12.03 kW input, COP 2.71 at -20/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss SZ120-4 (R134a scroll, 60 Hz, A/C) Catalog | Danfoss | R134a compressor — 24.8 kW cooling, 7.43 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AG4555U-TZ1A (R290 hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R290 compressor — 13.1 kW cooling, 5.07 kW input, COP 2.59 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4YHXF46KE-TSK (R455A Discus recip, 60 Hz, LD) Catalog | Copeland | R455A compressor — 14.4 kW cooling, 8.25 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss VZH052CJM (R454B inverter scroll) Catalog | Danfoss | R454B compressor — 27.0 kW cooling, 9.62 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AJ2464Z-TZ1C (R452A hermetic, LBP, EN12900, 60 Hz) Catalog | Tecumseh | R452A compressor — 0.72 kW cooling, 0.82 kW input, COP 0.89 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 4YHXS14ME-TSK (R455A Discus recip, 60 Hz, MD) Catalog | Copeland | R455A compressor — 32.5 kW cooling, 12.03 kW input, COP 2.71 at -20/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss DCJ121T7A (R454B scroll, 60 Hz) Catalog | Danfoss | R454B compressor — 34.2 kW cooling, 10.23 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4524Z-XG1A (R452A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R452A compressor — 5.0 kW cooling, 2.11 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4YJNF59KL-TSK (R455A Discus recip, 60 Hz, LD) Catalog | Copeland | R455A compressor — 17.9 kW cooling, 10.20 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss DSH140-9 (R452B scroll, 60 Hz, HT) Catalog | Danfoss | R452B compressor — 41.0 kW cooling, 12.51 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AE4450Z-FZ1A (R449A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Tecumseh | R449A compressor — 1.4 kW cooling, 0.58 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4YJXF59KE-TSK (R455A Discus recip, 60 Hz, LD) Catalog | Copeland | R455A compressor — 17.9 kW cooling, 10.20 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HLJ083T5 (R410A scroll, 50 Hz, A/C) Catalog | Danfoss | R410A compressor — 19.1 kW cooling, 7.01 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AG4561P-TZ1A (R404A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R404A compressor — 11.8 kW cooling, 5.73 kW input, COP 2.07 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4YKNF46KE-TSK (R455A Discus recip, 60 Hz, LD) Catalog | Copeland | R455A compressor — 14.4 kW cooling, 8.25 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRH036U4 (R410A scroll, 60 Hz, A/C) Catalog | Danfoss | R410A compressor — 10.4 kW cooling, 3.47 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AJ2464Z-XA3C (R404A hermetic, LBP, EN12900, 50 Hz) Catalog | Tecumseh | R404A compressor — 0.70 kW cooling, 0.80 kW input, COP 0.88 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 4YRNF59KE-TSK (R455A Discus recip, 60 Hz, LD) Catalog | Copeland | R455A compressor — 17.9 kW cooling, 10.20 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRM047U2 (R22 scroll, 50 Hz, A/C) Catalog | Danfoss | R22 compressor — 11.5 kW cooling, 3.57 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4524Z-XG1A (R452A hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R452A compressor — 6.1 kW cooling, 2.57 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4YRNR27ME-TSK (R455A Discus recip, 60 Hz, MD) Catalog | Copeland | R455A compressor — 47.4 kW cooling, 17.17 kW input, COP 2.76 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRP060T2 (R407C scroll, 50 Hz, A/C) Catalog | Danfoss | R407C compressor — 13.9 kW cooling, 4.53 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AE4450Z-FZ1A (R452A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Tecumseh | R452A compressor — 1.3 kW cooling, 0.61 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors