All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 817–840 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Embraco VEG7C (R600a variable-capacity hermetic, LBP, ASHRAE, 50-60 Hz) CatalogEmbracoR600a compressor — 0.11 kW cooling, 0.07 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW120J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogInvotechR134a compressor — 11.2 kW cooling, 3.36 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh FH2480P-XC3A (R455A hermetic, LBP, EN12900, 50 Hz) CatalogTecumsehR455A compressor — 1.00 kW cooling, 0.99 kW input, COP 1.01 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6YHXF68KE-TSK (R454A Discus recip, 60 Hz, LD) CatalogCopelandR454A compressor — 23.7 kW cooling, 13.93 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HLP072T1 (R407C scroll, 60 Hz, A/C) CatalogDanfossR407C compressor — 20.4 kW cooling, 6.52 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGC7H (R134a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogEmbracoR134a compressor — 0.20 kW cooling, 0.13 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF13E2G-Q102 (R404A low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogInvotechR404A compressor — 1.5 kW cooling, 1.39 kW input, COP 1.05 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh HG4512Z-FZ3A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR404A compressor — 2.3 kW cooling, 1.04 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YJNF84KL-TSK (R454A Discus recip, 60 Hz, LD) CatalogCopelandR454A compressor — 29.2 kW cooling, 17.27 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH029U2 (R410A scroll, 60 Hz, A/C) CatalogDanfossR410A compressor — 8.5 kW cooling, 2.84 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGD7H (R134a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogEmbracoR134a compressor — 0.21 kW cooling, 0.13 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH119A6-100 (R22 air-conditioning scroll, 50 Hz, 220 V 3P) CatalogInvotechR22 compressor — 12.0 kW cooling, 3.54 kW input, COP 3.38 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh HGA8510BXC (R410A hermetic, AC, ASHRAE, 50 Hz) CatalogTecumsehR410A compressor — 2.9 kW cooling, 0.82 kW input, COP 3.59 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YJNR39ME-TSN (R454A Discus recip, 60 Hz, MD) CatalogCopelandR454A compressor — 75.7 kW cooling, 28.61 kW input, COP 2.65 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM032U1 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 9.5 kW cooling, 2.91 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGT11HB (R134a variable-capacity hermetic, LBP, ASHRAE, 50-60 Hz) CatalogEmbracoR134a compressor — 0.31 kW cooling, 0.20 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM115E1G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogInvotechR404A compressor — 17.8 kW cooling, 7.25 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh RG5512W-FZ4A (R407C hermetic, AC, EN12900, 50 Hz) CatalogTecumsehR407C compressor — 2.2 kW cooling, 0.90 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YJXF84KE-TSK (R454A Discus recip, 60 Hz, LD) CatalogCopelandR454A compressor — 29.2 kW cooling, 17.27 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP025T4 (R407C scroll, 60 Hz, A/C) CatalogDanfossR407C compressor — 6.9 kW cooling, 2.21 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGY6L (R1234yf variable-capacity hermetic, MBP, EN12900, 50-60 Hz) CatalogEmbracoR1234yf compressor — 0.18 kW cooling, 0.12 kW input, COP 1.45 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YSF65A5G-V100 (R22 low-temperature freezing scroll, 60 Hz, 380 V 3P) CatalogInvotechR22 compressor — 25.3 kW cooling, 9.56 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh RGA5492CXA (R407C hermetic, AC, EN12900, 60 Hz) CatalogTecumsehR407C compressor — 2.4 kW cooling, 0.85 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6YKNF68KE-TSK (R454A Discus recip, 60 Hz, LD) CatalogCopelandR454A compressor — 23.7 kW cooling, 13.93 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…3334353637…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors