All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 13,705–13,728 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZB21KCE-TF5 (R507 scroll, 60 Hz, MT) CatalogCopelandR507 compressor — 6.1 kW cooling, 2.51 kW input, COP 2.42 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZBD76K5E-TFD (R513A scroll, 50 Hz, HT) CatalogCopelandR513A compressor — 18.0 kW cooling, 6.53 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF11KQE-TF5 (R407F scroll, 60 Hz, LL) CatalogCopelandR407F compressor — 2.5 kW cooling, 2.08 kW input, COP 1.22 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZR57KCE-TFD (R22 scroll, 60 Hz, AC) CatalogCopelandR22 compressor — 17.2 kW cooling, 5.28 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZS33KAE-TF5 (R448A scroll, 60 Hz, EM) CatalogCopelandR448A compressor — 4.9 kW cooling, 3.07 kW input, COP 1.58 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YB51KAE-TFD (R134A scroll, 60 Hz, HT) CatalogCopelandR134a compressor — 16.8 kW cooling, 5.76 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland YF10KAE-TF5 (R454A scroll, 60 Hz, LL) CatalogCopelandR454A compressor — 3.3 kW cooling, 2.58 kW input, COP 1.27 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YS40KAE-TF5 (R454A scroll, 60 Hz, EM) CatalogCopelandR454A compressor — 7.1 kW cooling, 4.39 kW input, COP 1.62 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB21KCE-TF5 (R513A scroll, 60 Hz, HT) CatalogCopelandR513A compressor — 6.3 kW cooling, 2.34 kW input, COP 2.70 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZBD76K5E-TFD (R513A scroll, 60 Hz, HT) CatalogCopelandR513A compressor — 21.6 kW cooling, 7.83 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF11KQE-TF5 (R448A scroll, 50 Hz, LL) CatalogCopelandR448A compressor — 2.2 kW cooling, 1.71 kW input, COP 1.30 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZR57KCE-TFD (R407C scroll, 50 Hz, AC) CatalogCopelandR407C compressor — 13.4 kW cooling, 4.23 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZS33KAE-TF5 (R449A scroll, 50 Hz, EM) CatalogCopelandR449A compressor — 4.1 kW cooling, 2.57 kW input, COP 1.58 at -25/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland YB51KAE-TFD (R513A scroll, 60 Hz, HT) CatalogCopelandR513A compressor — 16.7 kW cooling, 6.12 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland YF10KAE-TF5 (R454C scroll, 50 Hz, LL) CatalogCopelandR454C compressor — 2.3 kW cooling, 1.75 kW input, COP 1.32 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland YS40KAE-TF5 (R454C scroll, 50 Hz, EM) CatalogCopelandR454C compressor — 5.1 kW cooling, 3.00 kW input, COP 1.69 at -25/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB21KF-PFS (R22 scroll, 50 Hz, HT) CatalogCopelandR22 compressor — 7.8 kW cooling, 2.58 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZBD76KCE-TF5 (R134A scroll, 50 Hz, HT) CatalogCopelandR134a compressor — 18.6 kW cooling, 6.18 kW input, COP 3.01 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF11KQE-TF5 (R448A scroll, 60 Hz, LL) CatalogCopelandR448A compressor — 2.7 kW cooling, 2.01 kW input, COP 1.34 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZR57KCE-TFD (R407C scroll, 60 Hz, AC) CatalogCopelandR407C compressor — 16.5 kW cooling, 5.11 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZS33KAE-TF5 (R449A scroll, 60 Hz, EM) CatalogCopelandR449A compressor — 4.9 kW cooling, 3.07 kW input, COP 1.58 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YB56K1G-TFD (R290 scroll, 50 Hz, MT) CatalogCopelandR290 compressor — 20.2 kW cooling, 6.69 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland YF10KAE-TF5 (R454C scroll, 60 Hz, LL) CatalogCopelandR454C compressor — 2.8 kW cooling, 2.09 kW input, COP 1.32 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YS40KAE-TF5 (R454C scroll, 60 Hz, EM) CatalogCopelandR454C compressor — 6.1 kW cooling, 3.61 kW input, COP 1.69 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…570571572573574…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors