All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 13,897–13,920 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZS45K4E-TF5 (R448A scroll, 50 Hz, EM) CatalogCopelandR448A compressor — 6.0 kW cooling, 3.21 kW input, COP 1.86 at -25/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland YB83KAE-TFD (R513A scroll, 60 Hz, HT) CatalogCopelandR513A compressor — 28.0 kW cooling, 9.89 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland YF19KAE-TF5 (R454C scroll, 60 Hz, LL) CatalogCopelandR454C compressor — 5.1 kW cooling, 3.66 kW input, COP 1.41 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB26KCE-TF5 (R407F scroll, 50 Hz, MT) CatalogCopelandR407F compressor — 5.1 kW cooling, 2.12 kW input, COP 2.39 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF13KQE-TF5 (R449A scroll, 50 Hz, ML) CatalogCopelandR449A compressor — 5.5 kW cooling, 2.15 kW input, COP 2.57 at -20/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZR72KTE-TFD (R407C scroll, 60 Hz, AC) CatalogCopelandR407C compressor — 21.2 kW cooling, 6.42 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZS45K4E-TF5 (R448A scroll, 60 Hz, EM) CatalogCopelandR448A compressor — 7.2 kW cooling, 3.85 kW input, COP 1.86 at -25/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YB97K1G-TFD (R290 scroll, 50 Hz, MT) CatalogCopelandR290 compressor — 35.6 kW cooling, 11.69 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland YF19KAE-TF5 (R455A scroll, 50 Hz, LL) CatalogCopelandR455A compressor — 4.6 kW cooling, 3.22 kW input, COP 1.44 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB26KCE-TF5 (R407F scroll, 60 Hz, MT) CatalogCopelandR407F compressor — 6.1 kW cooling, 2.54 kW input, COP 2.39 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF13KQE-TF5 (R449A scroll, 60 Hz, ML) CatalogCopelandR449A compressor — 6.8 kW cooling, 2.53 kW input, COP 2.68 at -20/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZR72KYE-TFD (R407C scroll, 50 Hz, AC) CatalogCopelandR407C compressor — 17.5 kW cooling, 5.34 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZS45K4E-TF5 (R449A scroll, 50 Hz, EM) CatalogCopelandR449A compressor — 6.0 kW cooling, 3.21 kW input, COP 1.86 at -25/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland YB97K1G-TFD (R290 scroll, 60 Hz, MT) CatalogCopelandR290 compressor — 42.7 kW cooling, 14.02 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland YF19KAE-TF5 (R455A scroll, 60 Hz, LL) CatalogCopelandR455A compressor — 5.6 kW cooling, 3.87 kW input, COP 1.44 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB26KCE-TF5 (R448A scroll, 50 Hz, MT) CatalogCopelandR448A compressor — 5.2 kW cooling, 2.16 kW input, COP 2.40 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF13KQE-TFC (R22 scroll, 50 Hz, LL) CatalogCopelandR22 compressor — 2.9 kW cooling, 2.08 kW input, COP 1.39 at -35/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZR72KYE-TFD (R407C scroll, 60 Hz, AC) CatalogCopelandR407C compressor — 21.3 kW cooling, 6.40 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZS45K4E-TF5 (R449A scroll, 60 Hz, EM) CatalogCopelandR449A compressor — 7.2 kW cooling, 3.85 kW input, COP 1.86 at -25/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YF22KAE-TFC (R454A scroll, 50 Hz, LL) CatalogCopelandR454A compressor — 5.9 kW cooling, 4.42 kW input, COP 1.34 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB26KCE-TF5 (R448A scroll, 60 Hz, MT) CatalogCopelandR448A compressor — 6.2 kW cooling, 2.60 kW input, COP 2.40 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF13KQE-TFC (R22 scroll, 60 Hz, LL) CatalogCopelandR22 compressor — 3.5 kW cooling, 2.29 kW input, COP 1.51 at -35/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZR81KCE-TF5 (R407C scroll, 50 Hz, AC) CatalogCopelandR407C compressor — 19.2 kW cooling, 5.81 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZS45K4E-TF5 (R507 scroll, 50 Hz, EM) CatalogCopelandR507 compressor — 6.5 kW cooling, 2.89 kW input, COP 2.23 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
‹ Previous1…578579580581582…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors