All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 13,849–13,872 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZS45K4E-TF5 (R134A scroll, 50 Hz, HT) CatalogCopelandR134a compressor — 11.0 kW cooling, 3.68 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland YB83KAE-TFD (R452A scroll, 60 Hz, MT) CatalogCopelandR452A compressor — 22.7 kW cooling, 10.85 kW input, COP 2.09 at -15/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YF15KAE-TF5 (R454A scroll, 60 Hz, LL) CatalogCopelandR454A compressor — 4.8 kW cooling, 3.68 kW input, COP 1.30 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB26KCE-TF5 (R134A scroll, 50 Hz, HT) CatalogCopelandR134a compressor — 6.2 kW cooling, 2.12 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF13K4E-TF5 (R448A scroll, 50 Hz, LL) CatalogCopelandR448A compressor — 3.6 kW cooling, 1.82 kW input, COP 1.99 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZR61KYE-TFD (R407C scroll, 50 Hz, AC) CatalogCopelandR407C compressor — 14.7 kW cooling, 4.55 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Copeland ZS45K4E-TF5 (R134A scroll, 60 Hz, HT) CatalogCopelandR134a compressor — 13.2 kW cooling, 4.41 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland YB83KAE-TFD (R454A scroll, 50 Hz, MT) CatalogCopelandR454A compressor — 20.1 kW cooling, 8.38 kW input, COP 2.39 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland YF15KAE-TF5 (R454C scroll, 50 Hz, LL) CatalogCopelandR454C compressor — 3.4 kW cooling, 2.50 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB26KCE-TF5 (R134A scroll, 60 Hz, HT) CatalogCopelandR134a compressor — 7.5 kW cooling, 2.54 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF13K4E-TF5 (R448A scroll, 60 Hz, LL) CatalogCopelandR448A compressor — 4.3 kW cooling, 2.18 kW input, COP 1.99 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZR68KCE-TFD (R407C scroll, 50 Hz, AC) CatalogCopelandR407C compressor — 16.4 kW cooling, 5.00 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZS45K4E-TF5 (R404A scroll, 50 Hz, EM) CatalogCopelandR404A compressor — 6.1 kW cooling, 2.79 kW input, COP 2.20 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland YB83KAE-TFD (R454A scroll, 60 Hz, MT) CatalogCopelandR454A compressor — 24.1 kW cooling, 10.05 kW input, COP 2.39 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YF15KAE-TF5 (R454C scroll, 60 Hz, LL) CatalogCopelandR454C compressor — 4.1 kW cooling, 3.00 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB26KCE-TF5 (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 5.7 kW cooling, 2.33 kW input, COP 2.43 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF13K4E-TF5 (R449A scroll, 50 Hz, LL) CatalogCopelandR449A compressor — 3.6 kW cooling, 1.82 kW input, COP 1.99 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZR68KCE-TFD (R407C scroll, 60 Hz, AC) CatalogCopelandR407C compressor — 20.1 kW cooling, 6.04 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZS45K4E-TF5 (R404A scroll, 60 Hz, EM) CatalogCopelandR404A compressor — 7.4 kW cooling, 3.35 kW input, COP 2.20 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YB83KAE-TFD (R454C scroll, 50 Hz, MT) CatalogCopelandR454C compressor — 17.4 kW cooling, 7.10 kW input, COP 2.45 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland YF15KAE-TF5 (R455A scroll, 50 Hz, ML) CatalogCopelandR455A compressor — 5.1 kW cooling, 2.38 kW input, COP 2.15 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB26KCE-TF5 (R404A scroll, 60 Hz, MT) CatalogCopelandR404A compressor — 6.8 kW cooling, 2.79 kW input, COP 2.43 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF13K4E-TF5 (R449A scroll, 60 Hz, LL) CatalogCopelandR449A compressor — 4.3 kW cooling, 2.18 kW input, COP 1.99 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZR68KTE-TFD (R407C scroll, 50 Hz, AC) CatalogCopelandR407C compressor — 16.4 kW cooling, 5.00 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder