All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 14,185–14,208 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZB45KCE-TF5 (R513A scroll, 60 Hz, HT) CatalogCopelandR513A compressor — 12.8 kW cooling, 4.51 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF28K4E-TFD (R507 scroll, 50 Hz, LL) CatalogCopelandR507 compressor — 9.4 kW cooling, 4.25 kW input, COP 2.21 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB45KQ-TFD (R22 scroll, 50 Hz, HT) CatalogCopelandR22 compressor — 16.3 kW cooling, 5.21 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Copeland ZF28K4E-TFD (R507 scroll, 60 Hz, LL) CatalogCopelandR507 compressor — 11.3 kW cooling, 5.10 kW input, COP 2.21 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB48KCE-TF5 (R134A scroll, 50 Hz, HT) CatalogCopelandR134a compressor — 12.1 kW cooling, 3.97 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF28KQE-TFC (R22 scroll, 50 Hz, ML) CatalogCopelandR22 compressor — 13.0 kW cooling, 6.21 kW input, COP 2.08 at -15/40 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R134A scroll, 60 Hz, HT) CatalogCopelandR134a compressor — 14.5 kW cooling, 4.77 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF28KQE-TFC (R404A scroll, 50 Hz, ML) CatalogCopelandR404A compressor — 13.6 kW cooling, 6.00 kW input, COP 2.27 at -15/40 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 11.0 kW cooling, 4.31 kW input, COP 2.54 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF28KQE-TFD (R22 scroll, 60 Hz, ML) CatalogCopelandR22 compressor — 15.7 kW cooling, 7.05 kW input, COP 2.22 at -15/40 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R404A scroll, 60 Hz, MT) CatalogCopelandR404A compressor — 13.2 kW cooling, 5.18 kW input, COP 2.54 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF28KQE-TFD (R404A scroll, 60 Hz, LL) CatalogCopelandR404A compressor — 7.7 kW cooling, 5.08 kW input, COP 1.52 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R407A scroll, 50 Hz, MT) CatalogCopelandR407A compressor — 9.8 kW cooling, 3.92 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF28KQE-TFD (R407A scroll, 50 Hz, ML) CatalogCopelandR407A compressor — 9.0 kW cooling, 3.66 kW input, COP 2.47 at -20/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R407A scroll, 60 Hz, MT) CatalogCopelandR407A compressor — 11.8 kW cooling, 4.70 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF28KQE-TFD (R448A scroll, 50 Hz, ML) CatalogCopelandR448A compressor — 12.0 kW cooling, 4.75 kW input, COP 2.52 at -20/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R407C scroll, 50 Hz, HT) CatalogCopelandR407C compressor — 19.1 kW cooling, 5.98 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF28KQE-TFD (R448A scroll, 60 Hz, LL) CatalogCopelandR448A compressor — 6.8 kW cooling, 5.57 kW input, COP 1.22 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R407C scroll, 60 Hz, HT) CatalogCopelandR407C compressor — 23.0 kW cooling, 7.18 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF28KQE-TFD (R449A scroll, 50 Hz, ML) CatalogCopelandR449A compressor — 12.0 kW cooling, 4.75 kW input, COP 2.52 at -20/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R407F scroll, 50 Hz, MT) CatalogCopelandR407F compressor — 9.8 kW cooling, 3.92 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF28KQE-TFD (R449A scroll, 60 Hz, LL) CatalogCopelandR449A compressor — 6.8 kW cooling, 5.57 kW input, COP 1.22 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB48KCE-TF5 (R407F scroll, 60 Hz, MT) CatalogCopelandR407F compressor — 11.8 kW cooling, 4.70 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF34K5E-TFD (R407A scroll, 60 Hz, LL) CatalogCopelandR407A compressor — 7.6 kW cooling, 5.55 kW input, COP 1.37 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…590591592593594…602Next ›