All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 14,137–14,160 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZB42KCE-PFV (R407A scroll, 60 Hz, MT) CatalogCopelandR407A compressor — 10.1 kW cooling, 4.15 kW input, COP 2.43 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF25KQE-TFD (R22 scroll, 50 Hz, LL) CatalogCopelandR22 compressor — 5.2 kW cooling, 3.99 kW input, COP 1.29 at -35/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB42KCE-PFV (R407C scroll, 60 Hz, HT) CatalogCopelandR407C compressor — 17.9 kW cooling, 6.20 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF25KQE-TFD (R404A scroll, 50 Hz, LL) CatalogCopelandR404A compressor — 5.5 kW cooling, 3.55 kW input, COP 1.54 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB42KCE-PFV (R407F scroll, 60 Hz, MT) CatalogCopelandR407F compressor — 10.1 kW cooling, 4.15 kW input, COP 2.43 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF25KQE-TFD (R404A scroll, 60 Hz, LL) CatalogCopelandR404A compressor — 6.6 kW cooling, 4.20 kW input, COP 1.57 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB42KCE-PFV (R448A scroll, 60 Hz, MT) CatalogCopelandR448A compressor — 10.3 kW cooling, 4.24 kW input, COP 2.44 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF25KQE-TFD (R407A scroll, 50 Hz, ML) CatalogCopelandR407A compressor — 7.7 kW cooling, 3.05 kW input, COP 2.52 at -20/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB42KCE-PFV (R449A scroll, 60 Hz, MT) CatalogCopelandR449A compressor — 10.3 kW cooling, 4.24 kW input, COP 2.44 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF25KQE-TFD (R407A scroll, 60 Hz, ML) CatalogCopelandR407A compressor — 11.5 kW cooling, 4.58 kW input, COP 2.52 at -20/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB42KCE-PFV (R507 scroll, 60 Hz, MT) CatalogCopelandR507 compressor — 11.7 kW cooling, 4.66 kW input, COP 2.51 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF25KQE-TFD (R407C scroll, 50 Hz, ML) CatalogCopelandR407C compressor — 12.5 kW cooling, 4.75 kW input, COP 2.64 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Copeland ZB42KCE-PFV (R513A scroll, 60 Hz, HT) CatalogCopelandR513A compressor — 12.2 kW cooling, 4.38 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF25KQE-TFD (R407C scroll, 60 Hz, ML) CatalogCopelandR407C compressor — 18.8 kW cooling, 7.13 kW input, COP 2.64 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Copeland ZB45KCE-TF5 (R134A scroll, 50 Hz, HT) CatalogCopelandR134a compressor — 10.9 kW cooling, 3.61 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF25KQE-TFD (R407F scroll, 50 Hz, LL) CatalogCopelandR407F compressor — 4.6 kW cooling, 3.64 kW input, COP 1.26 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB45KCE-TF5 (R134A scroll, 60 Hz, HT) CatalogCopelandR134a compressor — 13.1 kW cooling, 4.33 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF25KQE-TFD (R407F scroll, 60 Hz, LL) CatalogCopelandR407F compressor — 5.5 kW cooling, 4.37 kW input, COP 1.26 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB45KCE-TF5 (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 9.9 kW cooling, 3.91 kW input, COP 2.54 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25KQE-TFD (R507 scroll, 60 Hz, LL) CatalogCopelandR507 compressor — 6.6 kW cooling, 4.23 kW input, COP 1.55 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB45KCE-TF5 (R404A scroll, 60 Hz, MT) CatalogCopelandR404A compressor — 11.9 kW cooling, 4.69 kW input, COP 2.54 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF25KVE-TFD (R404A scroll, 50 Hz, LT) CatalogCopelandR404A compressor — 5.4 kW cooling, 3.55 kW input, COP 1.53 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB45KCE-TF5 (R407A scroll, 50 Hz, MT) CatalogCopelandR407A compressor — 8.9 kW cooling, 3.56 kW input, COP 2.48 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25KVE-TFD (R404A scroll, 60 Hz, LT) CatalogCopelandR404A compressor — 6.6 kW cooling, 4.23 kW input, COP 1.55 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…588589590591592…602Next ›