Showing 14,113–14,136 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZB38KFE-TFP (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 8.2 kW cooling, 3.23 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R407C scroll, 50 Hz, LL) CatalogCopelandR407C compressor — 5.9 kW cooling, 2.93 kW input, COP 2.01 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB42KCE-PFJ (R134A scroll, 50 Hz, HT) CatalogCopelandR134a compressor — 10.3 kW cooling, 3.49 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R407C scroll, 60 Hz, LL) CatalogCopelandR407C compressor — 7.1 kW cooling, 3.52 kW input, COP 2.01 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB42KCE-PFJ (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 9.4 kW cooling, 3.79 kW input, COP 2.48 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R407F scroll, 50 Hz, LL) CatalogCopelandR407F compressor — 6.4 kW cooling, 3.10 kW input, COP 2.05 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB42KCE-PFJ (R407A scroll, 50 Hz, MT) CatalogCopelandR407A compressor — 8.4 kW cooling, 3.46 kW input, COP 2.43 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R407F scroll, 60 Hz, LL) CatalogCopelandR407F compressor — 7.6 kW cooling, 3.72 kW input, COP 2.05 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB42KCE-PFJ (R407C scroll, 50 Hz, HT) CatalogCopelandR407C compressor — 14.9 kW cooling, 5.17 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R448A scroll, 50 Hz, LL) CatalogCopelandR448A compressor — 6.6 kW cooling, 3.18 kW input, COP 2.07 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB42KCE-PFJ (R407F scroll, 50 Hz, MT) CatalogCopelandR407F compressor — 8.4 kW cooling, 3.46 kW input, COP 2.43 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R448A scroll, 60 Hz, LL) CatalogCopelandR448A compressor — 7.9 kW cooling, 3.82 kW input, COP 2.07 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB42KCE-PFJ (R448A scroll, 50 Hz, MT) CatalogCopelandR448A compressor — 8.6 kW cooling, 3.53 kW input, COP 2.44 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R449A scroll, 50 Hz, LL) CatalogCopelandR449A compressor — 6.6 kW cooling, 3.18 kW input, COP 2.07 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB42KCE-PFJ (R449A scroll, 50 Hz, MT) CatalogCopelandR449A compressor — 8.6 kW cooling, 3.53 kW input, COP 2.44 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R449A scroll, 60 Hz, LL) CatalogCopelandR449A compressor — 7.9 kW cooling, 3.82 kW input, COP 2.07 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB42KCE-PFJ (R507 scroll, 50 Hz, MT) CatalogCopelandR507 compressor — 9.8 kW cooling, 3.88 kW input, COP 2.51 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R507 scroll, 50 Hz, LL) CatalogCopelandR507 compressor — 8.1 kW cooling, 3.56 kW input, COP 2.26 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB42KCE-PFJ (R513A scroll, 50 Hz, HT) CatalogCopelandR513A compressor — 10.1 kW cooling, 3.65 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R507 scroll, 60 Hz, LL) CatalogCopelandR507 compressor — 9.7 kW cooling, 4.27 kW input, COP 2.26 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB42KCE-PFV (R134A scroll, 60 Hz, HT) CatalogCopelandR134a compressor — 12.4 kW cooling, 4.18 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF25KQE-TFC (R22 scroll, 60 Hz, LL) CatalogCopelandR22 compressor — 6.2 kW cooling, 4.79 kW input, COP 1.29 at -35/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB42KCE-PFV (R404A scroll, 60 Hz, MT) CatalogCopelandR404A compressor — 11.3 kW cooling, 4.55 kW input, COP 2.48 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF25KQE-TFC (R507 scroll, 50 Hz, ML) CatalogCopelandR507 compressor — 11.6 kW cooling, 5.00 kW input, COP 2.31 at -15/40 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder