All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 14,089–14,112 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZB38KCE-TF5 (R407C scroll, 60 Hz, MT) CatalogCopelandR407C compressor — 8.4 kW cooling, 3.47 kW input, COP 2.43 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF18KQE-TFD (R407A scroll, 50 Hz, LL) CatalogCopelandR407A compressor — 3.6 kW cooling, 2.92 kW input, COP 1.24 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB38KCE-TF5 (R407F scroll, 50 Hz, MT) CatalogCopelandR407F compressor — 7.5 kW cooling, 3.06 kW input, COP 2.44 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF18KQE-TFD (R407A scroll, 60 Hz, LL) CatalogCopelandR407A compressor — 4.4 kW cooling, 3.43 kW input, COP 1.28 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB38KCE-TF5 (R407F scroll, 60 Hz, MT) CatalogCopelandR407F compressor — 9.0 kW cooling, 3.67 kW input, COP 2.44 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF18KQE-TFD (R407C scroll, 60 Hz, LL) CatalogCopelandR407C compressor — 4.0 kW cooling, 3.16 kW input, COP 1.28 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB38KCE-TF5 (R448A scroll, 50 Hz, MT) CatalogCopelandR448A compressor — 7.7 kW cooling, 3.12 kW input, COP 2.45 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF18KQE-TFD (R407F scroll, 50 Hz, LL) CatalogCopelandR407F compressor — 3.6 kW cooling, 2.92 kW input, COP 1.24 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB38KCE-TF5 (R448A scroll, 60 Hz, MT) CatalogCopelandR448A compressor — 9.2 kW cooling, 3.75 kW input, COP 2.45 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF18KQE-TFD (R407F scroll, 60 Hz, LL) CatalogCopelandR407F compressor — 4.4 kW cooling, 3.43 kW input, COP 1.28 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB38KCE-TF5 (R449A scroll, 50 Hz, MT) CatalogCopelandR449A compressor — 7.7 kW cooling, 3.12 kW input, COP 2.45 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF18KQE-TFD (R507 scroll, 50 Hz, LL) CatalogCopelandR507 compressor — 4.4 kW cooling, 3.13 kW input, COP 1.41 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB38KCE-TF5 (R449A scroll, 60 Hz, MT) CatalogCopelandR449A compressor — 9.2 kW cooling, 3.75 kW input, COP 2.45 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF19K2E-TFD (R452A scroll, 60 Hz, MT) CatalogCopelandR452A compressor — 14.7 kW cooling, 5.43 kW input, COP 2.71 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB38KCE-TF5 (R507 scroll, 50 Hz, MT) CatalogCopelandR507 compressor — 8.7 kW cooling, 3.44 kW input, COP 2.52 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF19KVE-TFD (R452A scroll, 60 Hz, MT) CatalogCopelandR452A compressor — 15.6 kW cooling, 5.03 kW input, COP 3.10 at -15/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB38KCE-TF5 (R507 scroll, 60 Hz, MT) CatalogCopelandR507 compressor — 10.4 kW cooling, 4.13 kW input, COP 2.52 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF25K4E-TF5 (R404A scroll, 50 Hz, LL) CatalogCopelandR404A compressor — 7.7 kW cooling, 3.44 kW input, COP 2.22 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB38KCE-TF5 (R513A scroll, 50 Hz, HT) CatalogCopelandR513A compressor — 9.0 kW cooling, 3.23 kW input, COP 2.79 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF25K4E-TF5 (R404A scroll, 60 Hz, LL) CatalogCopelandR404A compressor — 9.2 kW cooling, 4.13 kW input, COP 2.22 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB38KCE-TF5 (R513A scroll, 60 Hz, HT) CatalogCopelandR513A compressor — 10.8 kW cooling, 3.87 kW input, COP 2.79 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF25K4E-TF5 (R407A scroll, 50 Hz, LL) CatalogCopelandR407A compressor — 6.4 kW cooling, 3.10 kW input, COP 2.05 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB38KF-TFP (R22 scroll, 50 Hz, HT) CatalogCopelandR22 compressor — 14.0 kW cooling, 4.49 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Copeland ZF25K4E-TF5 (R407A scroll, 60 Hz, LL) CatalogCopelandR407A compressor — 7.6 kW cooling, 3.72 kW input, COP 2.05 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder