Compressors
Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.
The builder models these: pick one into a design and it solves on the listing's figures.
Showing 14,329–14,352 of 14,438
Tecumseh TA1360M-GS1A (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.08 kW cooling, 0.08 kW input, COP 1.00 at -35/45 °C (evaporating/condensing), inside its published envelope.
Tecumseh TA1370M-GS1A (R600a hermetic, LBP, EN12900, 50 Hz)
R600a compressor — 0.08 kW cooling, 0.09 kW input, COP 0.90 at -35/45 °C (evaporating/condensing), inside its published envelope.
Tecumseh TA1370M-GS1A (R600a hermetic, LBP, EN12900, 60 Hz)
R600a compressor — 0.09 kW cooling, 0.09 kW input, COP 0.97 at -35/45 °C (evaporating/condensing), inside its published envelope.
Tecumseh TA1370Y-FZ1D (R134a hermetic, LBP, ASHRAE, 50 Hz)
R134a compressor — 0.08 kW cooling, 0.08 kW input, COP 1.07 at -35/45 °C (evaporating/condensing), inside its published envelope.
Tecumseh TAG4553Z (R404A recip, EN 12900)
R404A compressor — 10.6 kW cooling, 5.06 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TAJ4517Z (R448A recip, EN 12900)
R448A compressor — 3.4 kW cooling, 1.56 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC3410Y-UZ1B (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 0.25 kW cooling, 0.12 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC3410Y-UZ1B (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.29 kW cooling, 0.14 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC3410Y-UZ1B (R513A hermetic, HBP, EN12900, 50 Hz)
R513A compressor — 0.25 kW cooling, 0.13 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC3410Y-UZ1B (R513A hermetic, HBP, EN12900, 60 Hz)
R513A compressor — 0.29 kW cooling, 0.15 kW input, COP 1.88 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4410Y-DT1B (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.29 kW cooling, 0.14 kW input, COP 2.07 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4410Y-DT1B (R513A hermetic, HBP, EN12900, 60 Hz)
R513A compressor — 0.29 kW cooling, 0.15 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4415Y-DT1B (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.46 kW cooling, 0.24 kW input, COP 1.92 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4415Y-DT1B (R513A hermetic, HBP, EN12900, 60 Hz)
R513A compressor — 0.47 kW cooling, 0.25 kW input, COP 1.85 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4415Y-UZ1B (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 0.39 kW cooling, 0.18 kW input, COP 2.12 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4415Y-UZ1B (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.46 kW cooling, 0.22 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4415Y-UZ1B (R513A hermetic, HBP, EN12900, 50 Hz)
R513A compressor — 0.39 kW cooling, 0.19 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4415Y-UZ1B (R513A hermetic, HBP, EN12900, 60 Hz)
R513A compressor — 0.47 kW cooling, 0.23 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4419Y-DT1B (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.47 kW cooling, 0.26 kW input, COP 1.78 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4419Y-DT1B (R513A hermetic, HBP, EN12900, 60 Hz)
R513A compressor — 0.47 kW cooling, 0.27 kW input, COP 1.71 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4419Y-UZ1B (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 0.40 kW cooling, 0.19 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4419Y-UZ1B (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 0.48 kW cooling, 0.24 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4419Y-UZ1B (R513A hermetic, HBP, EN12900, 50 Hz)
R513A compressor — 0.41 kW cooling, 0.20 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
Tecumseh TC4419Y-UZ1B (R513A hermetic, HBP, EN12900, 60 Hz)
R513A compressor — 0.48 kW cooling, 0.25 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.