All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 48Systems 3,474Components 15,411Accessories 3

Showing 14,281–14,304 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZB57KCE-TF5 (R407A scroll, 50 Hz, MT) CatalogCopelandR407A compressor — 11.2 kW cooling, 4.45 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF41KQE-TFD (R507 scroll, 60 Hz, ML) CatalogCopelandR507 compressor — 23.8 kW cooling, 10.29 kW input, COP 2.31 at -15/40 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB57KCE-TF5 (R407A scroll, 60 Hz, MT) CatalogCopelandR407A compressor — 13.5 kW cooling, 5.33 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF49K5E-TFC (R404A scroll, 50 Hz, LL) CatalogCopelandR404A compressor — 10.8 kW cooling, 7.07 kW input, COP 1.53 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB57KCE-TF5 (R407C scroll, 50 Hz, HT) CatalogCopelandR407C compressor — 19.9 kW cooling, 6.83 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF49K5E-TFC (R404A scroll, 60 Hz, LL) CatalogCopelandR404A compressor — 13.1 kW cooling, 8.52 kW input, COP 1.53 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB57KCE-TF5 (R407C scroll, 60 Hz, HT) CatalogCopelandR407C compressor — 23.9 kW cooling, 8.20 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF49K5E-TFC (R507 scroll, 50 Hz, LL) CatalogCopelandR507 compressor — 11.2 kW cooling, 7.24 kW input, COP 1.55 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB57KCE-TF5 (R407F scroll, 50 Hz, MT) CatalogCopelandR407F compressor — 11.2 kW cooling, 4.45 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF49K5E-TFC (R507 scroll, 60 Hz, LL) CatalogCopelandR507 compressor — 13.5 kW cooling, 8.69 kW input, COP 1.55 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB57KCE-TF5 (R407F scroll, 60 Hz, MT) CatalogCopelandR407F compressor — 13.5 kW cooling, 5.33 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF49K5E-TFD (R407A scroll, 60 Hz, LL) CatalogCopelandR407A compressor — 11.1 kW cooling, 8.22 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB57KCE-TF5 (R448A scroll, 50 Hz, MT) CatalogCopelandR448A compressor — 11.5 kW cooling, 4.54 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF49K5E-TFD (R407C scroll, 60 Hz, LL) CatalogCopelandR407C compressor — 10.3 kW cooling, 7.98 kW input, COP 1.29 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB57KCE-TF5 (R448A scroll, 60 Hz, MT) CatalogCopelandR448A compressor — 13.8 kW cooling, 5.45 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF49K5E-TFD (R407F scroll, 50 Hz, LL) CatalogCopelandR407F compressor — 9.3 kW cooling, 6.85 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB57KCE-TF5 (R449A scroll, 50 Hz, MT) CatalogCopelandR449A compressor — 11.5 kW cooling, 4.54 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF49K5E-TFD (R407F scroll, 60 Hz, LL) CatalogCopelandR407F compressor — 11.1 kW cooling, 8.22 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB57KCE-TF5 (R449A scroll, 60 Hz, MT) CatalogCopelandR449A compressor — 13.8 kW cooling, 5.45 kW input, COP 2.53 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF49K5E-TFD (R448A scroll, 50 Hz, LL) CatalogCopelandR448A compressor — 9.3 kW cooling, 5.93 kW input, COP 1.57 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB57KCE-TF5 (R507 scroll, 50 Hz, MT) CatalogCopelandR507 compressor — 13.0 kW cooling, 5.05 kW input, COP 2.58 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF49K5E-TFD (R448A scroll, 60 Hz, LL) CatalogCopelandR448A compressor — 11.3 kW cooling, 7.17 kW input, COP 1.58 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB57KCE-TF5 (R507 scroll, 60 Hz, MT) CatalogCopelandR507 compressor — 15.6 kW cooling, 6.06 kW input, COP 2.58 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF49K5E-TFD (R449A scroll, 50 Hz, LL) CatalogCopelandR449A compressor — 9.3 kW cooling, 5.93 kW input, COP 1.57 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
‹ Previous1…594595596597598…602Next ›