Compressors
Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.
The builder models these: pick one into a design and it solves on the listing's figures.
Showing 14,281–14,304 of 14,438
Tecumseh FH4544Z-XG1A (R452A hermetic, HBP, EN12900, 50 Hz)
R452A compressor — 8.8 kW cooling, 3.91 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.
Tecumseh FH4544Z-XG1A (R452A hermetic, HBP, EN12900, 60 Hz)
R452A compressor — 10.4 kW cooling, 4.61 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG4467U-FZ3A (R290 hermetic, HBP, EN12900, 50 Hz)
R290 compressor — 1.2 kW cooling, 0.44 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG4467Z-FZ3A (R404A hermetic, HBP, EN12900, 50 Hz)
R404A compressor — 1.3 kW cooling, 0.60 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG4492U-FZ3A (R290 hermetic, HBP, EN12900, 50 Hz)
R290 compressor — 1.6 kW cooling, 0.60 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG4492Z-FZ3A (R404A hermetic, HBP, EN12900, 50 Hz)
R404A compressor — 1.8 kW cooling, 0.79 kW input, COP 2.24 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG4512U-FZ3A (R290 hermetic, HBP, EN12900, 50 Hz)
R290 compressor — 2.0 kW cooling, 0.77 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG4512Z-FZ3A (R404A hermetic, HBP, EN12900, 50 Hz)
R404A compressor — 2.3 kW cooling, 1.04 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG5450N-FZ4A (R134a hermetic, AC, EN12900, 50 Hz)
R134a compressor — 1.1 kW cooling, 0.42 kW input, COP 2.66 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG5460N-FZ4A (R1234yf hermetic, AC, EN12900, 50 Hz)
R1234yf compressor — 1.2 kW cooling, 0.47 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG5460N-FZ4A (R134a hermetic, AC, EN12900, 50 Hz)
R134a compressor — 1.2 kW cooling, 0.47 kW input, COP 2.61 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG5472W-FZ4A (R407C hermetic, AC, EN12900, 50 Hz)
R407C compressor — 1.4 kW cooling, 0.54 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HG5512W-FZ4A (R407C hermetic, AC, EN12900, 50 Hz)
R407C compressor — 2.2 kW cooling, 0.90 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HGA2446ZFZ (R404A hermetic, LBP, ASHRAE, 50 Hz)
R404A compressor — 0.49 kW cooling, 0.53 kW input, COP 0.92 at -35/45 °C (evaporating/condensing), inside its published envelope.
Tecumseh HGA4476YFZ (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 1.6 kW cooling, 0.64 kW input, COP 2.53 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HGA5471BXC (R410A hermetic, AC, ASHRAE, 50 Hz)
R410A compressor — 1.7 kW cooling, 0.59 kW input, COP 2.83 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HGA5479BXC (R410A hermetic, AC, ASHRAE, 50 Hz)
R410A compressor — 1.7 kW cooling, 0.66 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HGA5510BXC (R410A hermetic, AC, ASHRAE, 50 Hz)
R410A compressor — 2.4 kW cooling, 0.87 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.
Tecumseh HGA8510BXC (R410A hermetic, AC, ASHRAE, 50 Hz)
R410A compressor — 2.9 kW cooling, 0.82 kW input, COP 3.59 at the AHRI 7.2/54.4 °C rating point.
Tecumseh RG5450N-FZ4A (R1234yf hermetic, AC, EN12900, 50 Hz)
R1234yf compressor — 1.0 kW cooling, 0.42 kW input, COP 2.47 at the AHRI 7.2/54.4 °C rating point.
Tecumseh RG5450N-FZ4A (R134a hermetic, AC, EN12900, 50 Hz)
R134a compressor — 1.1 kW cooling, 0.42 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.
Tecumseh RG5460N-FZ4A (R1234yf hermetic, AC, EN12900, 50 Hz)
R1234yf compressor — 1.2 kW cooling, 0.47 kW input, COP 2.49 at the AHRI 7.2/54.4 °C rating point.
Tecumseh RG5460N-FZ4A (R134a hermetic, AC, EN12900, 50 Hz)
R134a compressor — 1.2 kW cooling, 0.48 kW input, COP 2.59 at the AHRI 7.2/54.4 °C rating point.
Tecumseh RG5480W-FZ4A (R407C hermetic, AC, EN12900, 50 Hz)
R407C compressor — 1.6 kW cooling, 0.63 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors