Copeland ZB50KCE-TF5 (R449A scroll, 60 Hz, MT) CatalogCopelandR449A compressor — 12.6 kW cooling, 5.23 kW input, COP 2.41 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF41K5E-TFD (R449A scroll, 60 Hz, LL) CatalogCopelandR449A compressor — 9.5 kW cooling, 5.94 kW input, COP 1.60 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB50KCE-TF5 (R507 scroll, 50 Hz, MT) CatalogCopelandR507 compressor — 11.9 kW cooling, 4.83 kW input, COP 2.47 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF41KQE-TFD (R22 scroll, 50 Hz, LL) CatalogCopelandR22 compressor — 7.9 kW cooling, 5.41 kW input, COP 1.46 at -35/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB50KCE-TF5 (R507 scroll, 60 Hz, MT) CatalogCopelandR507 compressor — 14.3 kW cooling, 5.80 kW input, COP 2.47 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF41KQE-TFD (R22 scroll, 60 Hz, LL) CatalogCopelandR22 compressor — 9.5 kW cooling, 6.48 kW input, COP 1.46 at -35/30 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB50KCE-TF5 (R513A scroll, 50 Hz, HT) CatalogCopelandR513A compressor — 12.4 kW cooling, 4.55 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF41KQE-TFD (R404A scroll, 50 Hz, LL) CatalogCopelandR404A compressor — 8.5 kW cooling, 5.82 kW input, COP 1.45 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB50KCE-TF5 (R513A scroll, 60 Hz, HT) CatalogCopelandR513A compressor — 14.9 kW cooling, 5.46 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF41KQE-TFD (R404A scroll, 60 Hz, LL) CatalogCopelandR404A compressor — 10.3 kW cooling, 7.08 kW input, COP 1.46 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB50KQE-TF5 (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 11.4 kW cooling, 4.56 kW input, COP 2.51 at -15/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZF41KQE-TFD (R407A scroll, 50 Hz, LL) CatalogCopelandR407A compressor — 7.7 kW cooling, 5.59 kW input, COP 1.38 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB50KQE-TF5 (R404A scroll, 60 Hz, MD) CatalogCopelandR404A compressor — 10.4 kW cooling, 4.32 kW input, COP 2.40 at -25/25 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZF41KQE-TFD (R407A scroll, 60 Hz, LL) CatalogCopelandR407A compressor — 9.3 kW cooling, 6.74 kW input, COP 1.38 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB56K5U-TFM (R290 scroll, 50 Hz, MT) CatalogCopelandR290 compressor — 20.5 kW cooling, 6.59 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF41KQE-TFD (R407C scroll, 50 Hz, LL) CatalogCopelandR407C compressor — 7.1 kW cooling, 5.43 kW input, COP 1.30 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB57KCE-TF5 (R134A scroll, 50 Hz, HT) CatalogCopelandR134a compressor — 13.8 kW cooling, 4.58 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZF41KQE-TFD (R407C scroll, 60 Hz, LL) CatalogCopelandR407C compressor — 8.5 kW cooling, 6.51 kW input, COP 1.30 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB57KCE-TF5 (R134A scroll, 60 Hz, HT) CatalogCopelandR134a compressor — 16.5 kW cooling, 5.50 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZF41KQE-TFD (R407F scroll, 50 Hz, LL) CatalogCopelandR407F compressor — 8.1 kW cooling, 5.88 kW input, COP 1.37 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB57KCE-TF5 (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 12.5 kW cooling, 4.90 kW input, COP 2.56 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF41KQE-TFD (R407F scroll, 60 Hz, LL) CatalogCopelandR407F compressor — 9.7 kW cooling, 7.06 kW input, COP 1.37 at -35/35 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder
Copeland ZB57KCE-TF5 (R404A scroll, 60 Hz, MT) CatalogCopelandR404A compressor — 15.0 kW cooling, 5.88 kW input, COP 2.56 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF41KQE-TFD (R507 scroll, 50 Hz, ML) CatalogCopelandR507 compressor — 19.7 kW cooling, 8.46 kW input, COP 2.33 at -15/40 °C (evaporating/condensing), inside its published envelope.APACOpen in the builder