Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 2,761–2,784 of 10,248
Copeland YF05KSE-TF5 (R449A scroll, 60 Hz, LL)
R449A compressor — 1.5 kW cooling, 1.28 kW input, COP 1.20 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF05KSE-TF5 (R454A scroll, 50 Hz, LL)
R454A compressor — 1.9 kW cooling, 1.01 kW input, COP 1.85 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland YF05KSE-TF5 (R454A scroll, 60 Hz, LL)
R454A compressor — 2.2 kW cooling, 1.21 kW input, COP 1.85 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland YF05KSE-TF5 (R454C scroll, 50 Hz, LL)
R454C compressor — 1.6 kW cooling, 0.85 kW input, COP 1.86 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland YF05KSE-TF5 (R454C scroll, 60 Hz, LL)
R454C compressor — 1.9 kW cooling, 1.02 kW input, COP 1.86 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland YF05KSE-TF5 (R455A scroll, 50 Hz, LL)
R455A compressor — 1.7 kW cooling, 0.90 kW input, COP 1.92 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland YF05KSE-TF5 (R455A scroll, 60 Hz, LL)
R455A compressor — 2.1 kW cooling, 1.08 kW input, COP 1.92 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland YF05KSE-TF5 (R507 scroll, 50 Hz, LL)
R507 compressor — 1.5 kW cooling, 1.16 kW input, COP 1.32 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF05KSE-TF5 (R507 scroll, 60 Hz, LL)
R507 compressor — 1.8 kW cooling, 1.39 kW input, COP 1.32 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R404A scroll, 50 Hz, LL)
R404A compressor — 1.3 kW cooling, 1.15 kW input, COP 1.15 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R404A scroll, 60 Hz, LL)
R404A compressor — 1.6 kW cooling, 1.38 kW input, COP 1.15 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R407A scroll, 50 Hz, LL)
R407A compressor — 1.1 kW cooling, 1.04 kW input, COP 1.08 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R407A scroll, 60 Hz, LL)
R407A compressor — 1.4 kW cooling, 1.25 kW input, COP 1.08 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R407C scroll, 50 Hz, LL)
R407C compressor — 1.0 kW cooling, 0.99 kW input, COP 1.05 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R407C scroll, 60 Hz, LL)
R407C compressor — 1.2 kW cooling, 1.19 kW input, COP 1.05 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R407F scroll, 50 Hz, LL)
R407F compressor — 1.1 kW cooling, 1.04 kW input, COP 1.08 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R407F scroll, 60 Hz, LL)
R407F compressor — 1.4 kW cooling, 1.25 kW input, COP 1.08 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R448A scroll, 50 Hz, LL)
R448A compressor — 1.2 kW cooling, 1.05 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R448A scroll, 60 Hz, LL)
R448A compressor — 1.4 kW cooling, 1.25 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R449A scroll, 50 Hz, LL)
R449A compressor — 1.2 kW cooling, 1.05 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TFD (R449A scroll, 60 Hz, LL)
R449A compressor — 1.4 kW cooling, 1.25 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TF5 (R454A scroll, 50 Hz, LT)
R454A compressor — 1.3 kW cooling, 1.12 kW input, COP 1.13 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TF5 (R454A scroll, 60 Hz, LT)
R454A compressor — 1.5 kW cooling, 1.34 kW input, COP 1.13 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF06KAE-TF5 (R454C scroll, 50 Hz, LT)
R454C compressor — 1.1 kW cooling, 0.96 kW input, COP 1.11 at -35/35 °C (evaporating/condensing), inside its published envelope.
Publishing here