Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 2,857–2,880 of 10,248
Copeland YF08KAE-TFD (R407C scroll, 60 Hz, LL)
R407C compressor — 1.7 kW cooling, 1.63 kW input, COP 1.04 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TFD (R407F scroll, 50 Hz, LL)
R407F compressor — 1.5 kW cooling, 1.42 kW input, COP 1.09 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TFD (R407F scroll, 60 Hz, LL)
R407F compressor — 1.8 kW cooling, 1.68 kW input, COP 1.09 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TFD (R448A scroll, 50 Hz, LL)
R448A compressor — 1.6 kW cooling, 1.46 kW input, COP 1.11 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TFD (R448A scroll, 60 Hz, LL)
R448A compressor — 2.0 kW cooling, 1.74 kW input, COP 1.13 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TFD (R449A scroll, 50 Hz, LL)
R449A compressor — 1.6 kW cooling, 1.46 kW input, COP 1.11 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TFD (R449A scroll, 60 Hz, LL)
R449A compressor — 2.0 kW cooling, 1.74 kW input, COP 1.13 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TF5 (R454A scroll, 50 Hz, LT)
R454A compressor — 1.7 kW cooling, 1.47 kW input, COP 1.19 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TF5 (R454A scroll, 60 Hz, LT)
R454A compressor — 2.1 kW cooling, 1.76 kW input, COP 1.19 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TF5 (R454C scroll, 50 Hz, LT)
R454C compressor — 1.5 kW cooling, 1.26 kW input, COP 1.17 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TF5 (R454C scroll, 60 Hz, LT)
R454C compressor — 1.8 kW cooling, 1.51 kW input, COP 1.17 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TF5 (R455A scroll, 50 Hz, LT)
R455A compressor — 1.6 kW cooling, 1.32 kW input, COP 1.21 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TF5 (R455A scroll, 60 Hz, LT)
R455A compressor — 1.9 kW cooling, 1.59 kW input, COP 1.21 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TFD (R507 scroll, 50 Hz, LL)
R507 compressor — 1.8 kW cooling, 1.57 kW input, COP 1.16 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAE-TFD (R507 scroll, 60 Hz, LL)
R507 compressor — 2.2 kW cooling, 1.87 kW input, COP 1.19 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAU-TF5 (R290 scroll, 50 Hz, LT)
R290 compressor — 1.6 kW cooling, 1.17 kW input, COP 1.39 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF08KAU-TF5 (R290 scroll, 60 Hz, LT)
R290 compressor — 2.0 kW cooling, 1.41 kW input, COP 1.39 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF09KSE-PFV (R404A scroll, 50 Hz, LL)
R404A compressor — 2.5 kW cooling, 1.84 kW input, COP 1.34 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF09KSE-PFV (R407A scroll, 50 Hz, LL)
R407A compressor — 2.1 kW cooling, 1.68 kW input, COP 1.24 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF09KSE-PFV (R407F scroll, 50 Hz, LL)
R407F compressor — 2.1 kW cooling, 1.68 kW input, COP 1.24 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF09KSE-PFV (R448A scroll, 50 Hz, LL)
R448A compressor — 2.2 kW cooling, 1.74 kW input, COP 1.24 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF09KSE-PFV (R449A scroll, 50 Hz, LL)
R449A compressor — 2.2 kW cooling, 1.74 kW input, COP 1.24 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland YF09KSE-TF5 (R454A scroll, 50 Hz, LL)
R454A compressor — 3.2 kW cooling, 1.60 kW input, COP 2.00 at -30/25 °C (evaporating/condensing), inside its published envelope.
Copeland YF09KSE-TF5 (R454A scroll, 60 Hz, LL)
R454A compressor — 3.8 kW cooling, 1.92 kW input, COP 2.00 at -30/25 °C (evaporating/condensing), inside its published envelope.
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one