Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.

Suppliers 26Systems 3,346Components 10,248
All kindsCompressor 9,761Pump 260Fan 173Heater 40Evaporative media 5Recovery core 5Heat pipe 3Coil 1
All marketsEU 5,807NA 4,975APAC 3,696CN 1,283LATAM 1,283MEA 1
All tagsR404A 1,129R134a 1,064R407C 941R448A 845R22 735R449A 661R290 541R410A 506R407F 479R407A 477R454C 348R455A 342+13 more — search by name instead
All suppliersCopeland 5,452Tecumseh 1,891Embraco 1,283Invotech 1,103Grundfos 223Ziehl-Abegg 171KSB 33Bitzer 25Powrmatic 22Reznor 6Systemair 6Recair 5+9 more — search by name instead
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 3,073–3,096 of 10,248

Copeland YH11K1E-TFD (R1234yf scroll, 60 Hz, HP)

R1234yf compressor — 10.4 kW cooling, 3.54 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.

catalogR1234yf
Compressor · NA

Copeland YH11K1E-TFD (R134A scroll, 60 Hz, HP)

R134a compressor — 11.0 kW cooling, 3.43 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Copeland YH11K1E-TFD (R407C scroll, 60 Hz, HP)

R407C compressor — 16.2 kW cooling, 5.19 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland YH11K1E-TFD (R454C scroll, 60 Hz, HP)

R454C compressor — 14.9 kW cooling, 4.94 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.

catalogR454C
Compressor · NA

Copeland YH11K1E-TFD (R513A scroll, 60 Hz, HP)

R513A compressor — 11.4 kW cooling, 3.71 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.

catalogR513A
Compressor · NA

Copeland YH13K1E-PFJ (R1234yf scroll, 50 Hz, HP)

R1234yf compressor — 9.9 kW cooling, 3.47 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.

catalogR1234yf
Compressor · EU, APAC

Copeland YH13K1E-TFD (R1234yf scroll, 60 Hz, HP)

R1234yf compressor — 12.2 kW cooling, 4.14 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.

catalogR1234yf
Compressor · NA

Copeland YH13K1E-TFD (R134A scroll, 60 Hz, HP)

R134a compressor — 13.1 kW cooling, 4.00 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Copeland YH13K1E-PFJ (R407C scroll, 50 Hz, HP)

R407C compressor — 15.8 kW cooling, 5.43 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU, APAC

Copeland YH13K1E-TFD (R407C scroll, 60 Hz, HP)

R407C compressor — 19.2 kW cooling, 6.12 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland YH13K1E-TFD (R454C scroll, 60 Hz, HP)

R454C compressor — 17.7 kW cooling, 5.80 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.

catalogR454C
Compressor · NA

Copeland YH13K1E-TFD (R513A scroll, 60 Hz, HP)

R513A compressor — 13.5 kW cooling, 4.36 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.

catalogR513A
Compressor · NA

Copeland YH16K1E-TFD (R1234yf scroll, 60 Hz, HP)

R1234yf compressor — 15.6 kW cooling, 5.30 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.

catalogR1234yf
Compressor · NA

Copeland YH16K1E-TFD (R134A scroll, 60 Hz, HP)

R134a compressor — 17.1 kW cooling, 5.14 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Copeland YH16K1E-TFD (R407C scroll, 60 Hz, HP)

R407C compressor — 24.3 kW cooling, 7.78 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland YH16K1E-TFD (R454C scroll, 60 Hz, HP)

R454C compressor — 22.3 kW cooling, 7.40 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.

catalogR454C
Compressor · NA

Copeland YH16K1E-TFD (R513A scroll, 60 Hz, HP)

R513A compressor — 17.1 kW cooling, 5.56 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.

catalogR513A
Compressor · NA

Copeland YP154K1T-TFD (R32 scroll, 60 Hz, AC)

R32 compressor — 46.7 kW cooling, 14.18 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.

catalogR32
Compressor · NA

Copeland YP182K1T-TFD (R32 scroll, 50 Hz, AC)

R32 compressor — 45.0 kW cooling, 13.74 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.

catalogR32
Compressor · EU, APAC

Copeland YP182K1T-TFD (R32 scroll, 60 Hz, AC)

R32 compressor — 54.9 kW cooling, 16.72 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR32
Compressor · NA

Copeland YP195KNT-TFM (R32 scroll, 50 Hz, AC)

R32 compressor — 46.0 kW cooling, 14.75 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR32
Compressor · EU, APAC

Copeland YP195KPT-TFM (R32 scroll, 50 Hz, AC)

R32 compressor — 42.4 kW cooling, 14.75 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.

catalogR32
Compressor · EU, APAC

Copeland YP24K1T-TFD (R32 scroll, 50 Hz, AC)

R32 compressor — 5.8 kW cooling, 1.88 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.

catalogR32
Compressor · EU, APAC

Copeland YP29K1T-TFD (R32 scroll, 50 Hz, AC)

R32 compressor — 7.2 kW cooling, 2.29 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR32
Compressor · EU, APAC
‹ Previous1…127128129130131…427Next ›

Publishing here