Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 3,913–3,936 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss HRH031U4 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 9.1 kW cooling, 3.04 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT2168GKV (R404A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 0.41 kW cooling, 0.42 kW input, COP 0.98 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW285A1-100 (R22 heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 31.4 kW cooling, 9.60 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AE2420P-FZ1B (R448A hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 0.36 kW cooling, 0.27 kW input, COP 1.33 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DFDR15ME-TFD (R407F Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407F compressor — 23.4 kW cooling, 8.52 kW input, COP 2.75 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM038T9 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 10.9 kW cooling, 3.25 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NTU6240GKV (R404A hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 3.7 kW cooling, 1.69 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF25E2G-Q100 (R449A low-temperature freezing scroll, 50 Hz, 220 V 1P) CatalogCompressorsInvotechR449A compressor — 2.7 kW cooling, 2.52 kW input, COP 1.05 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh AG2516Z-KZ1A (R452A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 1.4 kW cooling, 1.51 kW input, COP 0.92 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DFDS11ME-TFD (R407F Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407F compressor — 20.2 kW cooling, 7.51 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP040T4 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 9.1 kW cooling, 3.14 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco VEGT8U (R290 variable-capacity hermetic, MBP, EN12900) CatalogCompressorsEmbracoR290 compressor — 0.45 kW cooling, 0.29 kW input, COP 1.55 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH175A1-100 (R22 air-conditioning scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR22 compressor — 17.6 kW cooling, 5.10 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AGB4553ZTZ (R407C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 10.6 kW cooling, 4.42 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DKHR15ML-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 49.6 kW cooling, 16.03 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss LLZ013T2C (R454C scroll, 50 Hz) CatalogCompressorsDanfossR454C compressor — 2.7 kW cooling, 1.70 kW input, COP 1.61 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco VEMY7C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsEmbracoR600a compressor — 0.13 kW cooling, 0.09 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM34E3G-100 (R449A medium-temperature refrigeration scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR449A compressor — 6.9 kW cooling, 2.60 kW input, COP 2.64 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2432Z-XA3B (R452A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 0.30 kW cooling, 0.38 kW input, COP 0.79 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DPHR12ML-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 42.5 kW cooling, 13.01 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLM038T5 (R22 scroll, 60 Hz, MT) CatalogCompressorsDanfossR22 compressor — 16.0 kW cooling, 5.26 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EGAS80HLP (R134a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.17 kW cooling, 0.12 kW input, COP 1.35 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW285A1-100 (R22 heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR22 compressor — 37.7 kW cooling, 11.51 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJK513Z-FZ3B (R407C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 2.9 kW cooling, 1.25 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…162163164165166…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one