Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 3,985–4,008 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Invotech YH175A6-100 (R22 air-conditioning scroll, 50 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 17.6 kW cooling, 5.10 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AE2420P-FZ1B (R452A hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 0.27 kW cooling, 0.25 kW input, COP 1.09 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3YB3R11ME-TFC (R455A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR455A compressor — 20.3 kW cooling, 7.32 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss VZH035CH (R410A inverter scroll, A/C) CatalogCompressorsDanfossR410A compressor — 18.5 kW cooling, 6.40 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMX3111U (R290 hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR290 compressor — 0.13 kW cooling, 0.09 kW input, COP 1.35 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM34E6G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 220 V 3P) CatalogCompressorsInvotechR404A compressor — 5.6 kW cooling, 2.48 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AG2516Z-TZ1D (R404A hermetic, LBP, Tecumseh Europe, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 2.4 kW cooling, 1.95 kW input, COP 1.23 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3YBDR11ME-TFC (R455A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR455A compressor — 20.3 kW cooling, 7.32 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DCJ106T2 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 31.4 kW cooling, 9.77 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMY3117U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.20 kW cooling, 0.12 kW input, COP 1.67 at -25/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW285T1-100 (R407C heat-pump water heater scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR407C compressor — 30.1 kW cooling, 9.69 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AGB4553ZTZ (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 11.0 kW cooling, 4.69 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3YF3R14ME-TFC (R455A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR455A compressor — 24.2 kW cooling, 8.79 kW input, COP 2.75 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSF155-4 (R32 scroll, 50 Hz, HT) CatalogCompressorsDanfossR32 compressor — 34.2 kW cooling, 11.60 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMYS75HSP (R134a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF25E3G-Q100 (R449A low-temperature freezing scroll, 60 Hz, 220 V 1P) CatalogCompressorsInvotechR449A compressor — 3.2 kW cooling, 3.03 kW input, COP 1.05 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AJ2440P-FZ3A (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 0.41 kW cooling, 0.48 kW input, COP 0.85 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3YFDR14ME-TFC (R455A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR455A compressor — 24.2 kW cooling, 8.79 kW input, COP 2.75 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH105-4 (R452B scroll, 60 Hz, A/C) CatalogCompressorsDanfossR452B compressor — 31.9 kW cooling, 9.64 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EMZ66CLP (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR600a compressor — 0.16 kW cooling, 0.09 kW input, COP 1.81 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH175A7-100 (R22 air-conditioning scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR22 compressor — 21.1 kW cooling, 6.12 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJK513Z-FZ3B (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 3.0 kW cooling, 1.33 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3YFDS87KE-TFD (R454C Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR454C compressor — 15.9 kW cooling, 5.86 kW input, COP 2.71 at -20/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HCJ121T4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 29.7 kW cooling, 9.22 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…165166167168169…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one