Copeland ZF28KQE-TFD (R22 scroll, 60 Hz, ML)
R22 compressor — 15.7 kW cooling, 7.05 kW input, COP 2.22 at -15/40 °C (evaporating/condensing), inside its published envelope.
Copeland ZF28KQE-TFC (R404A scroll, 50 Hz, ML)
R404A compressor — 13.6 kW cooling, 6.00 kW input, COP 2.27 at -15/40 °C (evaporating/condensing), inside its published envelope.
Copeland ZF28KQE-TFD (R404A scroll, 60 Hz, LL)
R404A compressor — 7.7 kW cooling, 5.08 kW input, COP 1.52 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF28KQE-TFD (R407A scroll, 50 Hz, ML)
R407A compressor — 9.0 kW cooling, 3.66 kW input, COP 2.47 at -20/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZF28KQE-TFD (R448A scroll, 50 Hz, ML)
R448A compressor — 12.0 kW cooling, 4.75 kW input, COP 2.52 at -20/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZF28KQE-TFD (R448A scroll, 60 Hz, LL)
R448A compressor — 6.8 kW cooling, 5.57 kW input, COP 1.22 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF28KQE-TFD (R449A scroll, 50 Hz, ML)
R449A compressor — 12.0 kW cooling, 4.75 kW input, COP 2.52 at -20/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZF28KQE-TFD (R449A scroll, 60 Hz, LL)
R449A compressor — 6.8 kW cooling, 5.57 kW input, COP 1.22 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34K5E-TFD (R407A scroll, 60 Hz, LL)
R407A compressor — 7.6 kW cooling, 5.55 kW input, COP 1.37 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34K5E-TFD (R407C scroll, 60 Hz, LL)
R407C compressor — 7.1 kW cooling, 5.47 kW input, COP 1.29 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34K5E-TFD (R407F scroll, 50 Hz, LL)
R407F compressor — 6.3 kW cooling, 4.61 kW input, COP 1.37 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34K5E-TFD (R407F scroll, 60 Hz, LL)
R407F compressor — 7.6 kW cooling, 5.55 kW input, COP 1.37 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34K5E-TFD (R448A scroll, 50 Hz, LL)
R448A compressor — 6.3 kW cooling, 4.08 kW input, COP 1.54 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34K5E-TFD (R448A scroll, 60 Hz, LL)
R448A compressor — 7.5 kW cooling, 4.89 kW input, COP 1.54 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34K5E-TFD (R449A scroll, 60 Hz, LL)
R449A compressor — 7.5 kW cooling, 4.89 kW input, COP 1.54 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R22 scroll, 50 Hz, LL)
R22 compressor — 6.6 kW cooling, 4.38 kW input, COP 1.50 at -35/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R22 scroll, 60 Hz, LL)
R22 compressor — 7.9 kW cooling, 5.26 kW input, COP 1.50 at -35/30 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R404A scroll, 50 Hz, LL)
R404A compressor — 7.0 kW cooling, 4.77 kW input, COP 1.47 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R404A scroll, 60 Hz, LL)
R404A compressor — 8.4 kW cooling, 5.72 kW input, COP 1.47 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R407A scroll, 50 Hz, LL)
R407A compressor — 6.3 kW cooling, 4.61 kW input, COP 1.37 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R407A scroll, 60 Hz, LL)
R407A compressor — 7.6 kW cooling, 5.55 kW input, COP 1.37 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R407C scroll, 50 Hz, LL)
R407C compressor — 5.9 kW cooling, 4.55 kW input, COP 1.29 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R407C scroll, 60 Hz, LL)
R407C compressor — 7.1 kW cooling, 5.47 kW input, COP 1.29 at -35/35 °C (evaporating/condensing), inside its published envelope.
Copeland ZF34KQE-TFD (R407F scroll, 50 Hz, LL)
R407F compressor — 6.4 kW cooling, 4.72 kW input, COP 1.35 at -35/35 °C (evaporating/condensing), inside its published envelope.