Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 4,777–4,800 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Copeland YEV098AT-4X9 (R32 variable-speed scroll) CatalogCompressorsCopelandR32 compressor — 54.7 kW cooling, 14.29 kW input, COP 3.83 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss LLZ013T4A (R448A scroll, 50 Hz, LT) CatalogCompressorsDanfossR448A compressor — 2.3 kW cooling, 1.79 kW input, COP 1.27 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco NEK2134GK (R404A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR404A compressor — 0.31 kW cooling, 0.31 kW input, COP 1.00 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF29E7G-Q100 (R448A low-temperature freezing scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR448A compressor — 3.6 kW cooling, 3.24 kW input, COP 1.11 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AGB4561ZTZ (R449A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 15.3 kW cooling, 6.78 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland YF03KAE-TF5 (R454C scroll, 50 Hz, LT) CatalogCompressorsCopelandR454C compressor — 0.47 kW cooling, 0.50 kW input, COP 0.95 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLM066T4 (R22 scroll, 60 Hz, MT) CatalogCompressorsDanfossR22 compressor — 30.1 kW cooling, 9.14 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU2170UA (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR290 compressor — 0.47 kW cooling, 0.37 kW input, COP 1.27 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH230A8-100 (R22 air-conditioning scroll, 60 Hz, 575 V 3P) CatalogCompressorsInvotechR22 compressor — 27.9 kW cooling, 8.08 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2446P-TZ1A (R449A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 0.72 kW cooling, 0.72 kW input, COP 0.99 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland YFD32KAE-TFD (R454A scroll, 50 Hz, LL) CatalogCompressorsCopelandR454A compressor — 8.2 kW cooling, 6.13 kW input, COP 1.34 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ015T2 (R404A scroll, 60 Hz, MT) CatalogCompressorsDanfossR404A compressor — 3.2 kW cooling, 1.67 kW input, COP 1.90 at -20/35 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco NJ9232E (R22 hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR22 compressor — 3.8 kW cooling, 1.76 kW input, COP 2.16 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM43U1G-100 (R454C medium-temperature refrigeration scroll, 50 Hz, 380 V 3P) CatalogCompressorsInvotechR454C compressor — 6.6 kW cooling, 2.22 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh FH2511Z-XC3A (R448A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 1.9 kW cooling, 1.61 kW input, COP 1.17 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland YFH03KAE-TF5 (R407A scroll, 50 Hz, LT) CatalogCompressorsCopelandR407A compressor — 0.53 kW cooling, 0.58 kW input, COP 0.92 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MT032-5 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 8.1 kW cooling, 2.98 kW input, COP 2.70 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT2180GK (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR404A compressor — 0.49 kW cooling, 0.51 kW input, COP 0.96 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW75C1-100 (R410A heat-pump water heater scroll, 60 Hz, 460 V 3P) CatalogCompressorsInvotechR410A compressor — 10.4 kW cooling, 3.61 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AE2425Z-GS3C (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 0.31 kW cooling, 0.35 kW input, COP 0.87 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland YH06K1E-TFD (R134A scroll, 60 Hz, HP) CatalogCompressorsCopelandR134a compressor — 6.2 kW cooling, 1.95 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MTZ018-4 (R407A hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR407A compressor — 3.6 kW cooling, 1.50 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2S30HLR (R134a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.07 kW cooling, 0.05 kW input, COP 1.38 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF29E7G-Q100 (R449A low-temperature freezing scroll, 60 Hz, 220 V 3P) CatalogCompressorsInvotechR449A compressor — 3.6 kW cooling, 3.24 kW input, COP 1.11 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…198199200201202…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one