Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 4,969–4,992 of 10,248
Copeland ZR42K5E-TFD (R22 scroll, 50 Hz, AC)
R22 compressor — 9.9 kW cooling, 3.26 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42K5E-TFD (R22 scroll, 60 Hz, AC)
R22 compressor — 12.4 kW cooling, 3.74 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42K5E-PFJ (R407C scroll, 50 Hz, AC)
R407C compressor — 9.8 kW cooling, 3.21 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42K5E-PFJ (R407C scroll, 60 Hz, AC)
R407C compressor — 11.9 kW cooling, 3.93 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42KE-TFD (R22 scroll, 50 Hz, AC)
R22 compressor — 10.2 kW cooling, 3.09 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42KE-TFD (R22 scroll, 60 Hz, AC)
R22 compressor — 12.5 kW cooling, 3.75 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42KEE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 9.7 kW cooling, 3.11 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42KEE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 11.8 kW cooling, 3.74 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42KTE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 9.7 kW cooling, 3.10 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR42KTE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 11.8 kW cooling, 3.73 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR44K5E-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 10.3 kW cooling, 3.29 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR44K5E-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 12.4 kW cooling, 3.95 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR45KCE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 10.5 kW cooling, 3.34 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR45KEE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 10.5 kW cooling, 3.34 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR45KEE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 12.6 kW cooling, 4.01 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR45KTE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 10.5 kW cooling, 3.34 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR45KTE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 12.6 kW cooling, 4.01 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR47K3E-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 11.1 kW cooling, 3.58 kW input, COP 3.09 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR47K3E-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 13.3 kW cooling, 4.19 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR47KTE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 11.0 kW cooling, 3.44 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR47KTE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 13.1 kW cooling, 4.15 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR48K3E-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 11.4 kW cooling, 3.60 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR48K3E-TF5 (R407C scroll, 60 Hz, AC)
R407C compressor — 13.8 kW cooling, 4.33 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.
Copeland ZR48K5-TFE (R22 scroll, 60 Hz, AC)
R22 compressor — 14.1 kW cooling, 4.17 kW input, COP 3.38 at the AHRI 7.2/54.4 °C rating point.
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one