Copeland ZRD42KCE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 10.0 kW cooling, 3.13 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRD42KCE-PFJ (R407C scroll, 60 Hz, AC)
R407C compressor — 12.7 kW cooling, 4.16 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRD48KCE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 12.1 kW cooling, 3.77 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRD48KCE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 14.1 kW cooling, 4.40 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRD61KCE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 14.2 kW cooling, 4.61 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRD61KCE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 17.4 kW cooling, 5.73 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRD72KCE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 16.9 kW cooling, 5.37 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRD72KCE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 20.7 kW cooling, 6.53 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRD81KCE-TF7 (R407C scroll, 60 Hz, AC)
R407C compressor — 24.1 kW cooling, 7.92 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRDT14MCE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 33.2 kW cooling, 10.96 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRDT14MCE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 39.7 kW cooling, 12.68 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRDU13MCE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 36.7 kW cooling, 11.81 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH100KTE-TFD (R134A scroll, 50 Hz, AC)
R134a compressor — 16.7 kW cooling, 5.32 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH100KTE-TF7 (R134A scroll, 60 Hz, AC)
R134a compressor — 20.1 kW cooling, 6.28 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH100KTE-TF7 (R407C scroll, 60 Hz, AC)
R407C compressor — 29.6 kW cooling, 9.10 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH116KTE-TFD (R134A scroll, 50 Hz, AC)
R134a compressor — 19.0 kW cooling, 6.24 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH116KTE-TFD (R134A scroll, 60 Hz, AC)
R134a compressor — 23.5 kW cooling, 7.40 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH116KTE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 27.9 kW cooling, 9.05 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH116KTE-TF7 (R407C scroll, 60 Hz, AC)
R407C compressor — 35.2 kW cooling, 10.99 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH49KJE-TF7 (R134A scroll, 60 Hz, HT)
R134a compressor — 9.0 kW cooling, 3.14 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH60KTE-TFD (R407C scroll, 50 Hz, AC)
R407C compressor — 13.6 kW cooling, 4.45 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH60KTE-TFD (R407C scroll, 60 Hz, AC)
R407C compressor — 16.7 kW cooling, 5.43 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH61KJE-TF7 (R134A scroll, 60 Hz, HT)
R134a compressor — 11.0 kW cooling, 3.66 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
Copeland ZRH72KJE-TFD (R134A scroll, 50 Hz, HT)
R134a compressor — 10.9 kW cooling, 3.57 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.