Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 6,313–6,336 of 10,248
Embraco FMFT411Z (R134a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R134a compressor — 0.31 kW cooling, 0.24 kW input, COP 1.31 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMFT413U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.71 kW cooling, 0.45 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMFT413U (R290 variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.71 kW cooling, 0.45 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMFT415U (R290 variable-capacity hermetic, LBP, EN12900)
R290 compressor — 0.86 kW cooling, 0.56 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMFT415U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.92 kW cooling, 0.60 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMFT415U (R290 variable-capacity hermetic, MBP, EN12900)
R290 compressor — 0.86 kW cooling, 0.56 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMFT415U (R290 variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R290 compressor — 0.92 kW cooling, 0.60 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMR7-11C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.14 kW cooling, 0.12 kW input, COP 1.23 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMR7-11C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.14 kW cooling, 0.12 kW input, COP 1.23 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSA11C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.18 kW cooling, 0.13 kW input, COP 1.43 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSA11C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.18 kW cooling, 0.13 kW input, COP 1.43 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSA4C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSA4C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.06 kW cooling, 0.05 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSA9C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.43 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSA9C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.43 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSY11C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.18 kW cooling, 0.13 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSY11C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.18 kW cooling, 0.13 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSY7C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSY7C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSY9C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.15 kW cooling, 0.11 kW input, COP 1.35 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMSY9C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.15 kW cooling, 0.11 kW input, COP 1.35 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMXA4C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.05 kW cooling, 0.04 kW input, COP 1.48 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMXA4C (R600a variable-capacity hermetic, MBP, EN12900, 50-60 Hz)
R600a compressor — 0.05 kW cooling, 0.04 kW input, COP 1.48 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco FMXA6C (R600a variable-capacity hermetic, LBP, EN12900, 50-60 Hz)
R600a compressor — 0.08 kW cooling, 0.05 kW input, COP 1.51 at -30/40 °C (evaporating/condensing), inside its published envelope.
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one