Embraco NEK6210U (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 1.1 kW cooling, 0.57 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6210Z (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 1.1 kW cooling, 0.60 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6210Z (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 1.2 kW cooling, 0.61 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6212Z (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 1.2 kW cooling, 0.62 kW input, COP 1.89 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6212Z (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 1.4 kW cooling, 0.76 kW input, COP 1.79 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6213GK (R404A hermetic, MBP, EN12900, 50 Hz)
R404A compressor — 1.5 kW cooling, 0.93 kW input, COP 1.58 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6213GK (R404A hermetic, MBP, EN12900, 60 Hz)
R404A compressor — 1.6 kW cooling, 1.14 kW input, COP 1.41 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6213U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 1.3 kW cooling, 0.69 kW input, COP 1.92 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6213U (R290 hermetic, MBP, EN12900, 60 Hz)
R290 compressor — 1.6 kW cooling, 0.87 kW input, COP 1.88 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6214U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 1.3 kW cooling, 0.61 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6214Z (R134a hermetic, HBP, EN12900, 50 Hz)
R134a compressor — 1.3 kW cooling, 0.74 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6214Z (R134a hermetic, HBP, EN12900, 60 Hz)
R134a compressor — 1.5 kW cooling, 0.86 kW input, COP 1.78 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6217GK (R404A hermetic, MBP, EN12900, 50 Hz)
R404A compressor — 1.7 kW cooling, 1.00 kW input, COP 1.71 at the AHRI 7.2/54.4 °C rating point.
Embraco NEK6217U (R290 hermetic, MBP, EN12900, 50 Hz)
R290 compressor — 1.7 kW cooling, 0.74 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.
Embraco NEU1140U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.29 kW cooling, 0.22 kW input, COP 1.29 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2140GK (R404A hermetic, LBP, EN12900, 50 Hz)
R404A compressor — 0.27 kW cooling, 0.24 kW input, COP 1.10 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2140GK (R404A hermetic, LBP, EN12900, 60 Hz)
R404A compressor — 0.31 kW cooling, 0.27 kW input, COP 1.13 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2140U (R290 hermetic, LBP, EN12900, 50-60 Hz)
R290 compressor — 0.34 kW cooling, 0.27 kW input, COP 1.25 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2140U (R290 hermetic, LBP, EN12900, 50 Hz)
R290 compressor — 0.28 kW cooling, 0.23 kW input, COP 1.22 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2140U (R290 hermetic, LBP, EN12900, 60 Hz)
R290 compressor — 0.30 kW cooling, 0.30 kW input, COP 1.00 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2140Z (R134a hermetic, LBP, EN12900, 60 Hz)
R134a compressor — 0.35 kW cooling, 0.31 kW input, COP 1.14 at -30/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2145GK (R404A hermetic, LBP, EN12900, 60 Hz)
R404A compressor — 0.33 kW cooling, 0.32 kW input, COP 1.05 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2155GK (R404A hermetic, LBP, EN12900, 50 Hz)
R404A compressor — 0.35 kW cooling, 0.34 kW input, COP 1.04 at -35/40 °C (evaporating/condensing), inside its published envelope.
Embraco NEU2155GK (R404A hermetic, LBP, EN12900, 60 Hz)
R404A compressor — 0.41 kW cooling, 0.37 kW input, COP 1.13 at -35/40 °C (evaporating/condensing), inside its published envelope.