Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 6,961–6,984 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Danfoss PSH026-7E (R410A scroll, 60 Hz) Catalog | Compressors | Danfoss | R410A compressor — 34.7 kW cooling, 11.72 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2X3134U (R290 hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R290 compressor — 0.36 kW cooling, 0.23 kW input, COP 1.56 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AG4547N-TZ1A (R134a hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 9.8 kW cooling, 4.13 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2DA3F23KL-TFC (R407A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R407A compressor — 5.2 kW cooling, 3.12 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss SH240-7 (R410A scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R410A compressor — 54.0 kW cooling, 18.81 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2Y50HLT (R134a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.10 kW cooling, 0.07 kW input, COP 1.46 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AJ2464Z-HZ3C (R449A hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R449A compressor — 0.93 kW cooling, 1.01 kW input, COP 0.92 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 2DB3F25KL-TFC (R407A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R407A compressor — 5.7 kW cooling, 3.26 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss SM161-4 (R22 scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 39.0 kW cooling, 11.59 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2Y60CLC (R600a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.12 kW cooling, 0.08 kW input, COP 1.54 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh FH4524P-XN3A (R455A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R455A compressor — 6.1 kW cooling, 2.43 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2DC3R53KL-TFC (R448A Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R448A compressor — 8.7 kW cooling, 3.12 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss SZ115-6 (R407C scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 26.9 kW cooling, 8.49 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2Y60HLP (R134a hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.10 kW cooling, 0.08 kW input, COP 1.34 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AE4450U-FZ1A (R290 hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R290 compressor — 1.4 kW cooling, 0.56 kW input, COP 2.49 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2DD3R63KL-TFC (R407F Discus recip, 60 Hz, MT) Catalog | Compressors | Copeland | R407F compressor — 9.9 kW cooling, 3.57 kW input, COP 2.76 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss VZH052CJ (R410A inverter scroll) Catalog | Compressors | Danfoss | R410A compressor — 24.4 kW cooling, 9.34 kW input, COP 2.61 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2Y70CLC (R600a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R600a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.47 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AG4547N-TZ1A (R134a hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 11.6 kW cooling, 5.29 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 2DF3F16KL-TFC (R407A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R407A compressor — 3.7 kW cooling, 2.26 kW input, COP 1.66 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss DCJ121T4B (R454B scroll, 50 Hz) Catalog | Compressors | Danfoss | R454B compressor — 25.4 kW cooling, 8.58 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM2Y70HLP (R134a hermetic, LBP, ASHRAE, 50 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.15 kW cooling, 0.09 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AJ2464Z-HZ3C (R452A hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R452A compressor — 0.75 kW cooling, 0.88 kW input, COP 0.85 at -35/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 2DL3F20KL-TFC (R407F Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R407F compressor — 4.5 kW cooling, 2.64 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory