Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 7,057–7,080 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Danfoss HLJ083T4B (R410A scroll, 60 Hz) Catalog | Compressors | Danfoss | R410A compressor — 24.3 kW cooling, 7.55 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM30HNR (R134a hermetic, LBP, ASHRAE, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.13 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AG4553P-TZ1A (R448A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R448A compressor — 11.0 kW cooling, 4.69 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 3DSDS12ML-TFC (R407C Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R407C compressor — 22.0 kW cooling, 8.45 kW input, COP 2.60 at -20/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRH036U2 (R410A scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R410A compressor — 8.8 kW cooling, 3.13 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM3C60HLT (R134a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.63 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AJ2464Z-KZ1C (R449A hermetic, LBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R449A compressor — 0.82 kW cooling, 0.82 kW input, COP 1.00 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 3PA3F41KL-TFD (R410A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R410A compressor — 12.8 kW cooling, 7.66 kW input, COP 1.68 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRM047T5 (R22 scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 11.6 kW cooling, 3.72 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM3D50HLT (R134a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.11 kW cooling, 0.07 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh FH4524Z-KZ1A (R452A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R452A compressor — 6.3 kW cooling, 2.54 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 3PADF41KL-TFD (R410A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R410A compressor — 12.8 kW cooling, 7.66 kW input, COP 1.68 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRP058T4 (R407C scroll, 60 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 16.3 kW cooling, 5.07 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM3D60HLT (R134a hermetic, MBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AE4450Y-GS3C (R134a hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R134a compressor — 1.4 kW cooling, 0.54 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 3PADR13ML-TFD (R410A Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R410A compressor — 34.4 kW cooling, 12.48 kW input, COP 2.76 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss LLZ015T2C (R448A scroll, 50 Hz, LT) Catalog | Compressors | Danfoss | R448A compressor — 2.9 kW cooling, 2.24 kW input, COP 1.30 at -35/30 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Embraco EM3D60HLT+ (R134a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AG4553P-TZ1A (R448A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R448A compressor — 13.3 kW cooling, 5.93 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 3YA3R99KE-TFC (R455A Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R455A compressor — 17.2 kW cooling, 6.18 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ015T4 (R22 scroll, 50 Hz, MT) Catalog | Compressors | Danfoss | R22 compressor — 5.5 kW cooling, 1.92 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Embraco EM3D70HLT (R134a hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Embraco | R134a compressor — 0.15 kW cooling, 0.09 kW input, COP 1.65 at -30/40 °C (evaporating/condensing), inside its published envelope. | APAC, CN, EU, LATAM, NA | Open in the builder |
| Tecumseh AJ2464Z-KZ1C (R449A hermetic, LBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R449A compressor — 0.94 kW cooling, 0.95 kW input, COP 0.99 at -30/45 °C (evaporating/condensing), inside its published envelope. | EU | Open in the builder |
| Copeland 3YADR99KL-TFC (R455A Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R455A compressor — 17.2 kW cooling, 6.18 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one