Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 7,129–7,152 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss HRM047T9 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 13.8 kW cooling, 4.19 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM45HHR (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.35 kW cooling, 0.17 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4524Z-XC3A (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 5.1 kW cooling, 2.20 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DBXR20ME-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 36.4 kW cooling, 12.84 kW input, COP 2.84 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRP058T5 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 13.7 kW cooling, 4.33 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM45HHR (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.40 kW cooling, 0.20 kW input, COP 1.95 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4450Z-AA1A (R448A hermetic, HBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 1.7 kW cooling, 0.71 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DCNR20ML-TSK (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 74.2 kW cooling, 22.39 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss LLZ015T2C (R448A scroll, 60 Hz, LT) CatalogCompressorsDanfossR448A compressor — 3.8 kW cooling, 2.85 kW input, COP 1.32 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco EM45HHR (R134a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.43 kW cooling, 0.17 kW input, COP 2.61 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AG4553P-TZ1A (R452A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR452A compressor — 13.0 kW cooling, 6.19 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DE3S13ME-TSK (R449A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR449A compressor — 25.8 kW cooling, 9.32 kW input, COP 2.77 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T4 (R22 scroll, 60 Hz, MT) CatalogCompressorsDanfossR22 compressor — 6.7 kW cooling, 2.21 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM45HHR (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.50 kW cooling, 0.20 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AJ2464Z-TZ1C (R404A hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 0.79 kW cooling, 0.89 kW input, COP 0.89 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4DENF47KE-TSK (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 11.0 kW cooling, 6.43 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT056-4 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 12.8 kW cooling, 4.58 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM45HHR (R134a hermetic, MBP, EN12900, 50 Hz) CatalogCompressorsEmbracoR134a compressor — 0.35 kW cooling, 0.17 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh FH4524Z-XG1A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 4.9 kW cooling, 2.18 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DENR18ME-TSK (R407F Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407F compressor — 31.4 kW cooling, 11.03 kW input, COP 2.85 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ018-5 (R454C hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR454C compressor — 3.4 kW cooling, 1.33 kW input, COP 2.53 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM45HHR (R134a hermetic, MBP, EN12900, 60 Hz) CatalogCompressorsEmbracoR134a compressor — 0.40 kW cooling, 0.20 kW input, COP 1.95 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Tecumseh AE4450Z-AA1A (R449A hermetic, HBP, ASHRAE, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 1.7 kW cooling, 0.71 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DHNF63KL-TSK (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 14.7 kW cooling, 8.37 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…296297298299300…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one