Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 7,705–7,728 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4476N-CZ1A (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 1.8 kW cooling, 0.85 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DE3S13ML-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 25.8 kW cooling, 9.32 kW input, COP 2.77 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ125-3 (R134a scroll, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 24.6 kW cooling, 7.35 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4532P-XC3A (R455A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR455A compressor — 6.3 kW cooling, 2.25 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DENF47KE-TSK (R448A Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR448A compressor — 9.6 kW cooling, 5.64 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss VZH065CJD (R410A inverter scroll, A/C) CatalogCompressorsDanfossR410A compressor — 34.0 kW cooling, 11.62 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AE4460Z-GS3C (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 1.6 kW cooling, 0.82 kW input, COP 1.92 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DENR18ME-TSK (R448A Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR448A compressor — 25.8 kW cooling, 9.04 kW input, COP 2.86 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss DSH161-7 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 47.2 kW cooling, 14.77 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AG4575U-TZ1A (R290 hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR290 compressor — 18.5 kW cooling, 7.24 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DHNF63KL-TSK (R448A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR448A compressor — 15.6 kW cooling, 9.01 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH038U2A (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 11.0 kW cooling, 3.69 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4476N-CZ1A (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 2.1 kW cooling, 1.04 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DHNR22ME-TSK (R407C Discus recip, 60 Hz, MT) CatalogCompressorsCopelandR407C compressor — 36.3 kW cooling, 13.67 kW input, COP 2.66 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM051T4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 15.0 kW cooling, 4.46 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4532P-XG1A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 6.0 kW cooling, 2.63 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DHXF63KL-TSK (R448A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR448A compressor — 15.6 kW cooling, 9.01 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ015T4A (R404A scroll, 50 Hz, LT) CatalogCompressorsDanfossR404A compressor — 3.8 kW cooling, 2.48 kW input, COP 1.55 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AE4470E-FZ3C (R22 hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 1.9 kW cooling, 0.78 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DHXR22ME-TSK (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 74.1 kW cooling, 23.89 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ015T4A (R404A scroll, 50 Hz, MT) CatalogCompressorsDanfossR404A compressor — 4.9 kW cooling, 2.08 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AG4581P-TZ1A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 16.3 kW cooling, 7.64 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJNF76KL-TSK (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 18.2 kW cooling, 10.34 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT072-4 (R22 hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 16.9 kW cooling, 6.12 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…320321322323324…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one