Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 7,729–7,752 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4476N-CZ1A (R513A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR513A compressor — 1.7 kW cooling, 0.84 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJNR28ML-TSK (R407A Discus recip, 50 Hz, AC) CatalogCompressorsCopelandR407A compressor — 78.6 kW cooling, 25.82 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MTZ019-4 (R407C hermetic reciprocating, 50 Hz) CatalogCompressorsDanfossR407C compressor — 3.5 kW cooling, 1.38 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4532P-XG1A (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 7.3 kW cooling, 3.15 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJXF76KL-TSK (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 18.2 kW cooling, 10.34 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss NTZ108-4B (R454C hermetic reciprocating, 60 Hz) CatalogCompressorsDanfossR454C compressor — 3.1 kW cooling, 2.31 kW input, COP 1.32 at -30/35 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AE4470P-FZ3C (R404A hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 1.9 kW cooling, 0.84 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJXR28ME-TSK (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 87.7 kW cooling, 29.41 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss PSH030-4E (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 38.5 kW cooling, 12.51 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AG4581P-TZ1A (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 19.2 kW cooling, 9.66 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DK3S16ML-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 33.7 kW cooling, 12.52 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SH300-7 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 92.8 kW cooling, 28.64 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4476N-CZ1A (R513A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR513A compressor — 2.0 kW cooling, 1.08 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DKNR22ME-TSK (R407F Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407F compressor — 80.0 kW cooling, 25.26 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SZ125-3 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 34.9 kW cooling, 10.89 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4532P-XG1A (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 6.2 kW cooling, 2.44 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DKNS16ML-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 33.7 kW cooling, 12.52 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss VZH065CJM (R410A inverter scroll) CatalogCompressorsDanfossR410A compressor — 34.8 kW cooling, 12.90 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AE4470P-FZ3C (R448A hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 1.9 kW cooling, 0.78 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DRNR28ME-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 47.5 kW cooling, 17.00 kW input, COP 2.80 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH161-7 (R452B scroll, 60 Hz, HT) CatalogCompressorsDanfossR452B compressor — 46.9 kW cooling, 13.84 kW input, COP 3.39 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AG4581P-TZ1A (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 16.9 kW cooling, 7.08 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YANF36KL-TSK (R454A Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR454A compressor — 10.4 kW cooling, 6.14 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRH038U2A (R454B scroll, 50 Hz) CatalogCompressorsDanfossR454B compressor — 7.8 kW cooling, 3.00 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…321322323324325…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here