Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 7,777–7,800 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Tecumseh AJ4476N-FZ1A (R513A hermetic, HBP, Tecumseh Europe, 50 Hz) Catalog | Compressors | Tecumseh | R513A compressor — 1.8 kW cooling, 0.88 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4YKNF46KL-TSK (R454A Discus recip, 50 Hz, LD) Catalog | Compressors | Copeland | R454A compressor — 13.3 kW cooling, 7.83 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss SZ125-4 (R134a scroll, 50 Hz, HT) Catalog | Compressors | Danfoss | R134a compressor — 20.7 kW cooling, 6.19 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4532P-XG1A (R452A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R452A compressor — 7.4 kW cooling, 3.09 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4YRNF59KL-TSK (R454A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R454A compressor — 19.9 kW cooling, 11.70 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss VZH065CJM (R452B inverter scroll) Catalog | Compressors | Danfoss | R452B compressor — 33.3 kW cooling, 12.21 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AE4470P-FZ3C (R454C hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R454C compressor — 1.7 kW cooling, 0.68 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DGNR37ML-TSN (R407F Discus recip, 50 Hz, AC) Catalog | Compressors | Copeland | R407F compressor — 103.8 kW cooling, 34.00 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss DSH161-7 (R454B scroll, 60 Hz, HT) Catalog | Compressors | Danfoss | R454B compressor — 46.0 kW cooling, 13.79 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AG4581P-TZ1A (R449A hermetic, HBP, EN12900, 60 Hz) Catalog | Compressors | Tecumseh | R449A compressor — 19.9 kW cooling, 8.95 kW input, COP 2.22 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DHNF93KL-TSK (R407C Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R407C compressor — 18.7 kW cooling, 12.40 kW input, COP 1.50 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRH038U2A (R454B scroll, 60 Hz) Catalog | Compressors | Danfoss | R454B compressor — 10.6 kW cooling, 3.48 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AJ4476N-XA1A (R1234yf hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R1234yf compressor — 1.6 kW cooling, 0.80 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DHNR35ME-AWX (R404A Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R404A compressor — 27.2 kW cooling, 15.32 kW input, COP 1.78 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRM051U2 (R22 scroll, 50 Hz, A/C) Catalog | Compressors | Danfoss | R22 compressor — 12.8 kW cooling, 3.83 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4532P-XG1A (R454C hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R454C compressor — 5.7 kW cooling, 2.05 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DHXR35ME-TSK (R448A Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R448A compressor — 57.8 kW cooling, 20.52 kW input, COP 2.82 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss LLZ015T4A (R448A scroll, 50 Hz, LT) Catalog | Compressors | Danfoss | R448A compressor — 2.9 kW cooling, 2.24 kW input, COP 1.30 at -35/30 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Tecumseh AE4470P-FZ3C (R455A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Compressors | Tecumseh | R455A compressor — 1.8 kW cooling, 0.71 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DJNF11ME-TSK (R448A Discus recip, 60 Hz, LT) Catalog | Compressors | Copeland | R448A compressor — 27.4 kW cooling, 15.51 kW input, COP 1.77 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ015T4A (R407A scroll, 50 Hz, MT) Catalog | Compressors | Danfoss | R407A compressor — 5.5 kW cooling, 2.01 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AG4581P-TZ1A (R452A hermetic, HBP, EN12900, 50 Hz) Catalog | Compressors | Tecumseh | R452A compressor — 16.5 kW cooling, 7.39 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6DJNR40ME-TSE (R407F Discus recip, 50 Hz, MD) Catalog | Compressors | Copeland | R407F compressor — 55.6 kW cooling, 20.25 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss MT072-6 (R22 hermetic reciprocating, 50 Hz, MT) Catalog | Compressors | Danfoss | R22 compressor — 16.9 kW cooling, 6.12 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point. | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one