Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8041–8064 of 10248
R407C compressor — 36.2 kW cooling, 11.62 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 36.2 kW cooling, 11.62 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 36.2 kW cooling, 11.62 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 36.2 kW cooling, 11.62 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 30.3 kW cooling, 8.79 kW input, COP 3.44 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 33.1 kW cooling, 10.81 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 39.7 kW cooling, 12.96 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 35.3 kW cooling, 10.70 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 42.3 kW cooling, 12.85 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 42.3 kW cooling, 12.85 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 42.3 kW cooling, 12.85 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 33.5 kW cooling, 10.95 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 41.8 kW cooling, 13.64 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 41.8 kW cooling, 13.64 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 33.9 kW cooling, 10.81 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 40.6 kW cooling, 12.98 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 40.6 kW cooling, 12.98 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 40.6 kW cooling, 12.98 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 40.6 kW cooling, 12.98 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 37.5 kW cooling, 12.41 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 3.7 kW cooling, 1.32 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 4.5 kW cooling, 1.54 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 3.7 kW cooling, 1.39 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 39.8 kW cooling, 11.89 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one