Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8017–8040 of 10248
R134a compressor — 22.4 kW cooling, 6.76 kW input, COP 3.32 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 26.9 kW cooling, 8.04 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 26.9 kW cooling, 8.04 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 26.9 kW cooling, 8.04 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 26.9 kW cooling, 8.04 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 27.0 kW cooling, 8.36 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 32.4 kW cooling, 10.04 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 32.4 kW cooling, 10.04 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 32.4 kW cooling, 10.04 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 26.7 kW cooling, 8.90 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 32.1 kW cooling, 10.74 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 25.9 kW cooling, 8.44 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 31.1 kW cooling, 10.14 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 31.1 kW cooling, 10.14 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 31.1 kW cooling, 10.14 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 31.1 kW cooling, 10.14 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 29.8 kW cooling, 9.79 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 35.7 kW cooling, 11.75 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 35.7 kW cooling, 11.75 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 31.4 kW cooling, 9.60 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 37.7 kW cooling, 11.51 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 37.7 kW cooling, 11.51 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 37.7 kW cooling, 11.51 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 30.1 kW cooling, 9.69 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.