Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 7969–7992 of 10248
R134a compressor — 17.3 kW cooling, 5.29 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 17.6 kW cooling, 5.46 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 21.1 kW cooling, 6.54 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 21.1 kW cooling, 6.54 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 21.1 kW cooling, 6.54 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 17.7 kW cooling, 5.91 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 21.3 kW cooling, 7.12 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 21.3 kW cooling, 7.12 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 21.3 kW cooling, 7.12 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 21.3 kW cooling, 7.12 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 16.9 kW cooling, 5.51 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 20.3 kW cooling, 6.61 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 20.3 kW cooling, 6.61 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 20.3 kW cooling, 6.61 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 17.2 kW cooling, 5.29 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 20.6 kW cooling, 6.28 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 20.6 kW cooling, 6.28 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 20.6 kW cooling, 6.28 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 20.6 kW cooling, 6.28 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 20.4 kW cooling, 6.26 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 24.5 kW cooling, 7.59 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 20.4 kW cooling, 7.02 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.
R410A compressor — 24.5 kW cooling, 8.37 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 19.6 kW cooling, 6.32 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one