Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8257–8280 of 10248
R454C compressor — 0.6 kW cooling, 0.24 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 0.6 kW cooling, 0.25 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 0.7 kW cooling, 0.26 kW input, COP 2.59 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.8 kW cooling, 0.34 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.8 kW cooling, 0.37 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.9 kW cooling, 0.45 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.7 kW cooling, 0.31 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.7 kW cooling, 0.28 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.8 kW cooling, 0.34 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.8 kW cooling, 0.37 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 0.6 kW cooling, 0.36 kW input, COP 1.79 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 0.8 kW cooling, 0.33 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 0.8 kW cooling, 0.33 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 1.1 kW cooling, 0.38 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 0.7 kW cooling, 0.30 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 0.8 kW cooling, 0.33 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 0.8 kW cooling, 0.33 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 0.8 kW cooling, 0.35 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 0.7 kW cooling, 0.32 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 0.7 kW cooling, 0.35 kW input, COP 1.90 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 0.7 kW cooling, 0.31 kW input, COP 2.32 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 0.8 kW cooling, 0.34 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.1 kW cooling, 0.48 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 0.7 kW cooling, 0.35 kW input, COP 1.90 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one