Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 8,233–8,256 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4510P-FZ3A (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 2.3 kW cooling, 1.10 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DKNS16ML-TSK (R449A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR449A compressor — 33.7 kW cooling, 12.52 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH034-3E (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 45.4 kW cooling, 15.00 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4538Z-KZ1A (R452A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR452A compressor — 9.2 kW cooling, 4.02 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DRNR28ML-TSK (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 94.4 kW cooling, 30.98 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SZ147-4 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 42.3 kW cooling, 12.03 kW input, COP 3.52 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4510P-FZ3A (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 2.3 kW cooling, 1.15 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YANF36KL-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 12.5 kW cooling, 7.37 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss VZH088CJ (R410A inverter scroll) CatalogCompressorsDanfossR410A compressor — 42.1 kW cooling, 15.86 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4538Z-XC3A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 7.8 kW cooling, 3.43 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YAXF36KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 10.4 kW cooling, 5.98 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH184-4NN (R410A scroll, 50 Hz, HT) CatalogCompressorsDanfossR410A compressor — 38.9 kW cooling, 13.66 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4510P-FZ3A (R454C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR454C compressor — 2.0 kW cooling, 0.97 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YBXF40KL-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 13.8 kW cooling, 8.16 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH040U4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 10.2 kW cooling, 3.58 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4538Z-XC3A (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 8.2 kW cooling, 3.28 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YCNF40KL-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 13.8 kW cooling, 8.16 kW input, COP 1.70 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM058U1 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 16.9 kW cooling, 5.06 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4510P-FZ3A (R455A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR455A compressor — 2.2 kW cooling, 1.01 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YENF36KL-TSK (R454A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454A compressor — 12.5 kW cooling, 7.37 kW input, COP 1.69 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ015T9A (R449A scroll, 60 Hz, LT) CatalogCompressorsDanfossR449A compressor — 3.8 kW cooling, 2.85 kW input, COP 1.32 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh FH4538Z-XC3A (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 8.2 kW cooling, 3.28 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YHNS14ML-TSK (R454A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454A compressor — 35.7 kW cooling, 13.59 kW input, COP 2.63 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T4A (R513A scroll, 60 Hz, MT) CatalogCompressorsDanfossR513A compressor — 4.3 kW cooling, 1.64 kW input, COP 2.64 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…342343344345346…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here