Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 8,473–8,496 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4511Y-CZ3B (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 3.2 kW cooling, 1.51 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZB06KAE-TF5 (R407C scroll, 60 Hz, MT) CatalogCompressorsCopelandR407C compressor — 1.3 kW cooling, 0.62 kW input, COP 2.13 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH184-7 (R452B scroll, 60 Hz, HT) CatalogCompressorsDanfossR452B compressor — 52.2 kW cooling, 15.81 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4544Z-XG1A (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 9.0 kW cooling, 3.73 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZBD114K5E-TFD (R449A scroll, 60 Hz, MT) CatalogCompressorsCopelandR449A compressor — 29.7 kW cooling, 9.78 kW input, COP 3.04 at -15/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH041U2 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 12.1 kW cooling, 4.05 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4511Y-GZ3B (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 2.8 kW cooling, 1.18 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZBW050SE-4X9 (R449A variable-speed scroll) CatalogCompressorsCopelandR449A compressor — 18.0 kW cooling, 6.32 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss HRM058U7 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 16.9 kW cooling, 5.02 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4544Z-XG1A (R448A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 10.7 kW cooling, 4.40 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZE52KME-TFM (R32 scroll, 50 Hz, AC) CatalogCompressorsCopelandR32 compressor — 12.7 kW cooling, 4.00 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss LLZ018T2A (R448A scroll, 60 Hz, LT) CatalogCompressorsDanfossR448A compressor — 4.5 kW cooling, 3.09 kW input, COP 1.46 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AJ4511Y-HZ3C (R134a hermetic, HBP, Tecumseh Europe, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 3.6 kW cooling, 1.42 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZEV130AE-4X9 (R410A variable-speed scroll) CatalogCompressorsCopelandR410A compressor — 66.7 kW cooling, 19.16 kW input, COP 3.48 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss MLZ015T4B (R407C scroll, 50 Hz, MT) CatalogCompressorsDanfossR407C compressor — 5.7 kW cooling, 1.86 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4544Z-XG1A (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 9.0 kW cooling, 3.73 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZF03KAE-TF5 (R407F scroll, 60 Hz, LL) CatalogCompressorsCopelandR407F compressor — 0.64 kW cooling, 0.70 kW input, COP 0.92 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT125-9 (R22 hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 36.5 kW cooling, 12.80 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4513N-FZ3C (R1234yf hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR1234yf compressor — 2.6 kW cooling, 1.27 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZFD41K5E-TFD (R407C scroll, 60 Hz, LL) CatalogCompressorsCopelandR407C compressor — 8.5 kW cooling, 6.51 kW input, COP 1.30 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ022-3 (R448A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR448A compressor — 5.8 kW cooling, 2.41 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4544Z-XG1A (R449A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 10.7 kW cooling, 4.40 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZFH03KAE-TF5 (R407F scroll, 60 Hz, LT) CatalogCompressorsCopelandR407F compressor — 0.64 kW cooling, 0.70 kW input, COP 0.92 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss NTZ215-4B (R404A hermetic reciprocating, 60 Hz, LT) CatalogCompressorsDanfossR404A compressor — 3.2 kW cooling, 3.74 kW input, COP 0.86 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
‹ Previous1…352353354355356…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one