Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8521–8544 of 10248
R448A compressor — 17.0 kW cooling, 7.71 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 19.8 kW cooling, 10.98 kW input, COP 1.80 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 17.0 kW cooling, 7.71 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 19.8 kW cooling, 10.98 kW input, COP 1.80 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 16.5 kW cooling, 8.17 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 19.1 kW cooling, 11.61 kW input, COP 1.65 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 16.3 kW cooling, 8.55 kW input, COP 1.90 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 18.6 kW cooling, 11.49 kW input, COP 1.62 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 17.4 kW cooling, 7.78 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 19.8 kW cooling, 9.88 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 17.4 kW cooling, 7.78 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 19.8 kW cooling, 9.88 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 16.8 kW cooling, 8.25 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 19.3 kW cooling, 10.54 kW input, COP 1.83 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 15.4 kW cooling, 6.64 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 18.0 kW cooling, 8.39 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 16.1 kW cooling, 6.94 kW input, COP 2.32 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 17.4 kW cooling, 8.12 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 15.8 kW cooling, 8.70 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 17.1 kW cooling, 10.38 kW input, COP 1.65 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 16.9 kW cooling, 7.91 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 18.2 kW cooling, 9.44 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 16.9 kW cooling, 7.91 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 18.2 kW cooling, 9.44 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one