Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8665–8688 of 10248
R22 compressor — 10.4 kW cooling, 4.08 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 12.4 kW cooling, 5.08 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 9.5 kW cooling, 4.33 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 11.4 kW cooling, 5.39 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 9.5 kW cooling, 3.78 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 11.4 kW cooling, 4.71 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 9.9 kW cooling, 4.01 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 11.8 kW cooling, 5.00 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 9.9 kW cooling, 4.01 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 11.8 kW cooling, 5.00 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 9.6 kW cooling, 4.19 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 11.5 kW cooling, 5.22 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 10.4 kW cooling, 4.14 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 12.4 kW cooling, 5.26 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 9.5 kW cooling, 4.39 kW input, COP 2.17 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 11.4 kW cooling, 5.58 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 9.5 kW cooling, 3.84 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 11.4 kW cooling, 4.87 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 9.9 kW cooling, 4.07 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 11.8 kW cooling, 5.17 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 9.9 kW cooling, 4.07 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 11.8 kW cooling, 5.17 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 9.6 kW cooling, 4.25 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 11.5 kW cooling, 5.40 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one