Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8689–8712 of 10248
R134a compressor — 9.8 kW cooling, 4.13 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 11.6 kW cooling, 5.29 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 10.0 kW cooling, 4.39 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 11.9 kW cooling, 5.63 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 11.6 kW cooling, 4.76 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 14.0 kW cooling, 5.80 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 10.6 kW cooling, 5.05 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 12.9 kW cooling, 6.15 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 10.6 kW cooling, 4.41 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 12.9 kW cooling, 5.37 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 11.0 kW cooling, 4.68 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 13.3 kW cooling, 5.70 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 11.0 kW cooling, 4.68 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 13.3 kW cooling, 5.70 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 10.8 kW cooling, 4.88 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 13.0 kW cooling, 5.95 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 11.6 kW cooling, 4.77 kW input, COP 2.43 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 14.0 kW cooling, 6.03 kW input, COP 2.32 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 10.6 kW cooling, 5.06 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 12.9 kW cooling, 6.40 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 10.6 kW cooling, 4.42 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 12.9 kW cooling, 5.59 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 11.0 kW cooling, 4.69 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 13.3 kW cooling, 5.93 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one