Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8857–8880 of 10248
R448A compressor — 2.4 kW cooling, 1.16 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.4 kW cooling, 1.16 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 2.3 kW cooling, 1.25 kW input, COP 1.87 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 2.0 kW cooling, 1.01 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 2.2 kW cooling, 1.08 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.6 kW cooling, 1.56 kW input, COP 1.69 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.8 kW cooling, 1.42 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.8 kW cooling, 1.42 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 2.7 kW cooling, 1.50 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 2.4 kW cooling, 1.17 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 2.5 kW cooling, 1.33 kW input, COP 1.90 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.3 kW cooling, 1.30 kW input, COP 1.74 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.4 kW cooling, 1.16 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.4 kW cooling, 1.16 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 2.3 kW cooling, 1.25 kW input, COP 1.87 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.6 kW cooling, 1.56 kW input, COP 1.69 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.8 kW cooling, 1.42 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.8 kW cooling, 1.42 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 2.7 kW cooling, 1.50 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.2 kW cooling, 1.22 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.6 kW cooling, 1.50 kW input, COP 1.71 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.4 kW cooling, 1.11 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.7 kW cooling, 1.37 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.4 kW cooling, 1.11 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one