Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8905–8928 of 10248
R452A compressor — 3.2 kW cooling, 1.71 kW input, COP 1.87 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 2.8 kW cooling, 1.41 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 2.9 kW cooling, 1.48 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.6 kW cooling, 2.23 kW input, COP 1.61 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.8 kW cooling, 2.03 kW input, COP 1.89 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.8 kW cooling, 2.03 kW input, COP 1.89 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.7 kW cooling, 2.14 kW input, COP 1.73 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 3.7 kW cooling, 1.67 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 3.9 kW cooling, 1.89 kW input, COP 2.07 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.0 kW cooling, 1.75 kW input, COP 1.74 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.6 kW cooling, 2.24 kW input, COP 1.62 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.2 kW cooling, 1.59 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.9 kW cooling, 2.04 kW input, COP 1.90 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.2 kW cooling, 1.59 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.9 kW cooling, 2.04 kW input, COP 1.90 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.1 kW cooling, 1.68 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.7 kW cooling, 2.16 kW input, COP 1.74 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 2.9 kW cooling, 1.33 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 3.4 kW cooling, 1.58 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 3.1 kW cooling, 1.50 kW input, COP 2.07 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 3.6 kW cooling, 1.78 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 3.0 kW cooling, 1.43 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 3.5 kW cooling, 1.82 kW input, COP 1.92 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 3.1 kW cooling, 1.63 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one