Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 8,953–8,976 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4519Z-FZ3C (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 4.3 kW cooling, 2.17 kW input, COP 1.96 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DD3R63KL-TFD (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 21.5 kW cooling, 6.56 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss PSH034-9 (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 44.7 kW cooling, 14.62 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-GZ3C (R22 hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 4.6 kW cooling, 2.04 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DF3F16KL-TFD (R513A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR513A compressor — 7.3 kW cooling, 2.78 kW input, COP 2.65 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ160-4 (R404A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR404A compressor — 42.0 kW cooling, 16.04 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-GZ3C (R404A hermetic, HBP, Tecumseh Europe, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 5.0 kW cooling, 2.10 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DL3R78KE-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 26.6 kW cooling, 7.97 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss VZH170BJ (R410A inverter scroll, A/C) CatalogCompressorsDanfossR410A compressor — 83.5 kW cooling, 30.33 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-GZ3C (R407C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 4.4 kW cooling, 1.91 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YA3R82KL-TFC (R454A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454A compressor — 15.5 kW cooling, 5.68 kW input, COP 2.73 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH240-7 (R452B scroll, 60 Hz, A/C) CatalogCompressorsDanfossR452B compressor — 70.4 kW cooling, 21.28 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-GZ3C (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 4.6 kW cooling, 2.04 kW input, COP 2.24 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YL3R73KL-TFC (R454A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454A compressor — 13.7 kW cooling, 5.04 kW input, COP 2.72 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH044U4 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 13.0 kW cooling, 4.31 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-GZ3C (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 4.6 kW cooling, 2.04 kW input, COP 2.24 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DA3R10ME-TFC (R407F Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407F compressor — 16.9 kW cooling, 6.22 kW input, COP 2.71 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ018T2C (R454C scroll, 50 Hz) CatalogCompressorsDanfossR454C compressor — 4.2 kW cooling, 2.39 kW input, COP 1.74 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AJ4519Z-GZ3C (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 4.5 kW cooling, 2.13 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DADF28KL-TFD (R513A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR513A compressor — 11.2 kW cooling, 4.27 kW input, COP 2.63 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T5 (R22 scroll, 50 Hz, MT) CatalogCompressorsDanfossR22 compressor — 5.6 kW cooling, 1.97 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-HZ3C (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 4.6 kW cooling, 2.75 kW input, COP 1.69 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DB3F33KL-TFD (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 8.3 kW cooling, 4.60 kW input, COP 1.81 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ022-4 (R407F hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR407F compressor — 5.2 kW cooling, 2.02 kW input, COP 2.57 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…372373374375376…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one