Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8953–8976 of 10248
R452A compressor — 3.7 kW cooling, 2.16 kW input, COP 1.74 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.1 kW cooling, 1.90 kW input, COP 1.63 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.6 kW cooling, 2.34 kW input, COP 1.54 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.3 kW cooling, 1.73 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.8 kW cooling, 2.13 kW input, COP 1.80 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.3 kW cooling, 1.73 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.8 kW cooling, 2.13 kW input, COP 1.80 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.2 kW cooling, 1.83 kW input, COP 1.75 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.7 kW cooling, 2.25 kW input, COP 1.65 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 4.1 kW cooling, 2.43 kW input, COP 1.68 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 4.3 kW cooling, 2.21 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 4.3 kW cooling, 2.21 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 4.2 kW cooling, 2.34 kW input, COP 1.80 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 3.8 kW cooling, 1.93 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 4.1 kW cooling, 2.02 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 4.7 kW cooling, 2.85 kW input, COP 1.65 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 5.0 kW cooling, 2.59 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 5.0 kW cooling, 2.59 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 4.8 kW cooling, 2.75 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 4.5 kW cooling, 2.19 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 4.8 kW cooling, 2.49 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 4.0 kW cooling, 2.43 kW input, COP 1.64 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 4.5 kW cooling, 3.02 kW input, COP 1.50 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 4.2 kW cooling, 2.21 kW input, COP 1.92 at the AHRI 7.2/54.4 °C rating point.