Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 8,929–8,952 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4519P-TZ1A (R454C hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR454C compressor — 3.9 kW cooling, 2.07 kW input, COP 1.90 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZRH60KTE-TFD (R407C scroll, 50 Hz, AC) CatalogCompressorsCopelandR407C compressor — 13.6 kW cooling, 4.45 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss VZH170BG (R410A inverter scroll, A/C) CatalogCompressorsDanfossR410A compressor — 84.1 kW cooling, 29.79 kW input, COP 2.82 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519P-TZ1A (R455A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR455A compressor — 4.0 kW cooling, 1.83 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZS09KAE-TF5 (R407C scroll, 50 Hz, HT) CatalogCompressorsCopelandR407C compressor — 3.3 kW cooling, 1.23 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss DSH240-7 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 72.4 kW cooling, 22.50 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519P-TZ1A (R455A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR455A compressor — 4.6 kW cooling, 2.20 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZSH13KAE-TF5 (R22 scroll, 50 Hz, MT) CatalogCompressorsCopelandR22 compressor — 4.8 kW cooling, 1.65 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss HRH044U4 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 10.8 kW cooling, 3.92 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-FZ3C (R22 hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR22 compressor — 4.4 kW cooling, 2.07 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZW108KSE-TFP (R407C scroll, 50 Hz, HE) CatalogCompressorsCopelandR407C compressor — 37.4 kW cooling, 8.34 kW input, COP 4.49 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss HRM060U7 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 17.5 kW cooling, 5.19 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-FZ3C (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 4.2 kW cooling, 2.24 kW input, COP 1.87 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZWD72KAE-TFD (R407C scroll, 50 Hz, HP) CatalogCompressorsCopelandR407C compressor — 22.2 kW cooling, 5.35 kW input, COP 4.16 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss LLZ018T2C (R454A scroll, 60 Hz) CatalogCompressorsDanfossR454A compressor — 6.0 kW cooling, 3.37 kW input, COP 1.77 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AJ4519Z-FZ3C (R407C hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR407C compressor — 4.2 kW cooling, 1.95 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZX21KCE-PFJ (R134A scroll, 50 Hz, MT) CatalogCompressorsCopelandR134a compressor — 2.4 kW cooling, 1.48 kW input, COP 1.63 at -15/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ015T5 (R134a scroll, 50 Hz, MT) CatalogCompressorsDanfossR134a compressor — 3.8 kW cooling, 1.31 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-FZ3C (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 4.3 kW cooling, 2.08 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DA3F23KL-TFD (R513A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR513A compressor — 9.2 kW cooling, 3.51 kW input, COP 2.64 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT160-9 (R22 hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 45.9 kW cooling, 16.08 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-FZ3C (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 4.3 kW cooling, 2.08 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DB3F25KL-TFD (R513A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR513A compressor — 9.7 kW cooling, 3.68 kW input, COP 2.64 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ022-4 (R407C hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 6.3 kW cooling, 2.26 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…371372373374375…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one