R448A compressor — 4.7 kW cooling, 2.81 kW input, COP 1.68 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 4.2 kW cooling, 2.22 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 4.7 kW cooling, 2.81 kW input, COP 1.68 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 4.1 kW cooling, 2.35 kW input, COP 1.75 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 4.6 kW cooling, 2.98 kW input, COP 1.54 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 4.0 kW cooling, 2.51 kW input, COP 1.61 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 4.7 kW cooling, 2.91 kW input, COP 1.61 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 4.3 kW cooling, 2.28 kW input, COP 1.89 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 5.0 kW cooling, 2.65 kW input, COP 1.89 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 4.3 kW cooling, 2.28 kW input, COP 1.89 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 5.0 kW cooling, 2.65 kW input, COP 1.89 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 4.2 kW cooling, 2.42 kW input, COP 1.73 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 4.8 kW cooling, 2.81 kW input, COP 1.73 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 4.9 kW cooling, 2.01 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 4.9 kW cooling, 2.01 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.3 kW cooling, 0.69 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.6 kW cooling, 0.89 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.4 kW cooling, 0.73 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.7 kW cooling, 0.91 kW input, COP 1.87 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.4 kW cooling, 0.73 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.7 kW cooling, 0.94 kW input, COP 1.79 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.3 kW cooling, 0.72 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.4 kW cooling, 0.71 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.5 kW cooling, 0.75 kW input, COP 1.96 at the AHRI 7.2/54.4 °C rating point.