Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 9,049–9,072 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4519Z-TZ1C (R449A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR449A compressor — 4.8 kW cooling, 2.41 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJXR28ME-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 47.5 kW cooling, 17.00 kW input, COP 2.80 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH038-4 (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 50.3 kW cooling, 17.90 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-TZ1C (R452A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR452A compressor — 4.2 kW cooling, 2.12 kW input, COP 1.96 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DKNR22ML-TSK (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 74.1 kW cooling, 23.89 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SZ160-6 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 35.2 kW cooling, 11.76 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4519Z-TZ1C (R452A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR452A compressor — 4.7 kW cooling, 2.52 kW input, COP 1.85 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DRNR28ML-TSK (R407F Discus recip, 50 Hz, AC) CatalogCompressorsCopelandR407F compressor — 78.6 kW cooling, 25.82 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss VZH170CGM (R454B inverter scroll) CatalogCompressorsDanfossR454B compressor — 72.8 kW cooling, 23.88 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4YANF36KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 10.4 kW cooling, 5.98 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH240-9 (R454B scroll, 60 Hz, A/C) CatalogCompressorsDanfossR454B compressor — 68.1 kW cooling, 20.82 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4YBXF40KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 11.6 kW cooling, 6.64 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH044U4A (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 12.3 kW cooling, 4.16 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4YCNF40KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 11.6 kW cooling, 6.64 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ018T4 (R404A scroll, 50 Hz, LT) CatalogCompressorsDanfossR404A compressor — 4.5 kW cooling, 2.81 kW input, COP 1.61 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland 4YENF36KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 10.4 kW cooling, 5.98 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T5A (R134a scroll, 50 Hz, MT) CatalogCompressorsDanfossR134a compressor — 3.8 kW cooling, 1.31 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4YHNS14ML-TSK (R454C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454C compressor — 30.3 kW cooling, 11.24 kW input, COP 2.70 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ022-4 (R449A hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR449A compressor — 4.8 kW cooling, 2.02 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4YHXF46KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 13.5 kW cooling, 7.72 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH039-3 (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 50.3 kW cooling, 16.68 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4YHXS14ML-TSK (R454C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454C compressor — 30.3 kW cooling, 11.24 kW input, COP 2.70 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ160-9 (R134a scroll, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 32.3 kW cooling, 9.58 kW input, COP 3.38 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4YJXF59KL-TSK (R454C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR454C compressor — 16.8 kW cooling, 9.53 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…376377378379380…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one