Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 9049–9072 of 10248
R1234yf compressor — 1.4 kW cooling, 0.65 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.6 kW cooling, 0.79 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.5 kW cooling, 0.64 kW input, COP 2.35 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.8 kW cooling, 0.79 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.5 kW cooling, 0.68 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.8 kW cooling, 0.84 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.3 kW cooling, 0.70 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.6 kW cooling, 0.90 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.4 kW cooling, 0.70 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.7 kW cooling, 0.90 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.4 kW cooling, 0.74 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.7 kW cooling, 0.95 kW input, COP 1.84 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.6 kW cooling, 0.73 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.8 kW cooling, 0.91 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.4 kW cooling, 0.68 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.4 kW cooling, 0.70 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.7 kW cooling, 0.90 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.6 kW cooling, 0.80 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.9 kW cooling, 1.03 kW input, COP 1.83 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.8 kW cooling, 0.85 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 2.1 kW cooling, 1.04 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.7 kW cooling, 0.84 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 2.0 kW cooling, 1.08 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
R1234yf compressor — 1.6 kW cooling, 0.82 kW input, COP 1.96 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one