Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 9265–9288 of 10248
R404A compressor — 4.5 kW cooling, 1.97 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 3.3 kW cooling, 1.38 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 3.9 kW cooling, 1.70 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.5 kW cooling, 1.47 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 4.1 kW cooling, 1.81 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.5 kW cooling, 1.47 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 4.1 kW cooling, 1.81 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.4 kW cooling, 1.54 kW input, COP 2.22 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 4.0 kW cooling, 1.89 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 3.4 kW cooling, 1.56 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 4.0 kW cooling, 1.89 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.2 kW cooling, 1.68 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.8 kW cooling, 2.04 kW input, COP 1.84 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 3.2 kW cooling, 1.47 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 3.7 kW cooling, 1.78 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.4 kW cooling, 1.56 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.9 kW cooling, 1.89 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.4 kW cooling, 1.56 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.9 kW cooling, 1.89 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.3 kW cooling, 1.63 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.8 kW cooling, 1.98 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 3.9 kW cooling, 1.65 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 4.7 kW cooling, 1.98 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 4.7 kW cooling, 2.02 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.