Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 9241–9264 of 10248
R449A compressor — 3.4 kW cooling, 1.56 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.9 kW cooling, 1.89 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.3 kW cooling, 1.63 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.8 kW cooling, 1.98 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 2.9 kW cooling, 1.29 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 3.5 kW cooling, 1.55 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 3.1 kW cooling, 1.35 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 3.7 kW cooling, 1.66 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 3.4 kW cooling, 1.48 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.2 kW cooling, 1.60 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 3.2 kW cooling, 1.39 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.3 kW cooling, 1.48 kW input, COP 2.24 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.3 kW cooling, 1.48 kW input, COP 2.24 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.2 kW cooling, 1.55 kW input, COP 2.09 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 3.4 kW cooling, 1.42 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.9 kW cooling, 1.55 kW input, COP 2.49 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 3.3 kW cooling, 1.41 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 3.5 kW cooling, 1.50 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 3.5 kW cooling, 1.50 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 3.4 kW cooling, 1.57 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 4.5 kW cooling, 1.89 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 3.6 kW cooling, 1.47 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 4.2 kW cooling, 1.81 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.9 kW cooling, 1.60 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one