Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 9,601–9,624 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss MTZ028-1 (R134a hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 4.6 kW cooling, 1.90 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZFD41K5E-TFD (R448A scroll, 60 Hz, LL) CatalogCompressorsCopelandR448A compressor — 9.5 kW cooling, 5.94 kW input, COP 1.60 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH065-4 (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 82.6 kW cooling, 27.50 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZFH03KAE-TF5 (R449A scroll, 60 Hz, LT) CatalogCompressorsCopelandR449A compressor — 0.68 kW cooling, 0.72 kW input, COP 0.94 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ175-9 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 48.7 kW cooling, 15.28 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZH101KCE-TED (R513A scroll, 50 Hz, HR) CatalogCompressorsCopelandR513A compressor — 37.0 kW cooling, 12.63 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss DSH485-4 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 143.8 kW cooling, 43.03 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZJ44KHE-TF7 (R410A scroll, 60 Hz, AC) CatalogCompressorsCopelandR410A compressor — 13.3 kW cooling, 4.16 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss HRH051U4A (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 15.2 kW cooling, 4.84 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZP122KZE-TFD (R410A scroll, 60 Hz, AC) CatalogCompressorsCopelandR410A compressor — 37.0 kW cooling, 11.01 kW input, COP 3.36 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss LLZ024T2C (R454A scroll, 60 Hz) CatalogCompressorsDanfossR454A compressor — 7.5 kW cooling, 4.12 kW input, COP 1.82 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland ZPD54K5E-TFE (R410A scroll, 60 Hz, AC) CatalogCompressorsCopelandR410A compressor — 15.9 kW cooling, 5.03 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ019T1C (R404A scroll, 60 Hz, MT) CatalogCompressorsDanfossR404A compressor — 8.2 kW cooling, 3.26 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZPS30LXE-TFE (R410A scroll, 60 Hz, AC) CatalogCompressorsCopelandR410A compressor — 8.9 kW cooling, 2.91 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MTZ028-1 (R404A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR404A compressor — 7.4 kW cooling, 3.44 kW input, COP 2.16 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZPSU84K5E-TFD (R410A scroll, 60 Hz, AC) CatalogCompressorsCopelandR410A compressor — 25.7 kW cooling, 8.33 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss PSH065-4 (R454B scroll, 50 Hz) CatalogCompressorsDanfossR454B compressor — 65.8 kW cooling, 21.14 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZPV0662E-5E9 (R410A variable-speed scroll) CatalogCompressorsCopelandR410A compressor — 33.1 kW cooling, 10.69 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Danfoss SZ185-3 (R134a scroll, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 36.6 kW cooling, 11.10 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZR125KCE-TFD (R407C scroll, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 36.6 kW cooling, 10.86 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss DSH485-4 (R452B scroll, 50 Hz, HT) CatalogCompressorsDanfossR452B compressor — 103.7 kW cooling, 33.74 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZRD81KCE-TF7 (R407C scroll, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 24.1 kW cooling, 7.92 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HRH051U4A (R454B scroll, 50 Hz) CatalogCompressorsDanfossR454B compressor — 10.9 kW cooling, 3.83 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZRH72KJE-TFD (R134A scroll, 50 Hz, HT) CatalogCompressorsCopelandR134a compressor — 10.9 kW cooling, 3.57 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
‹ Previous1…399400401402403…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one