Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 9,697–9,720 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss MLZ019T1C (R455A scroll, 60 Hz) CatalogCompressorsDanfossR455A compressor — 8.2 kW cooling, 2.95 kW input, COP 2.77 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6YKNR32ML-TSK (R407F Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407F compressor — 116.4 kW cooling, 36.80 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MTZ028-1 (R452A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR452A compressor — 7.2 kW cooling, 3.18 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6YKXR32ML-TSK (R454A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454A compressor — 61.6 kW cooling, 23.27 kW input, COP 2.65 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH065-9 (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 82.6 kW cooling, 27.50 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6YRNR39ML-TSN (R454C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454C compressor — 64.8 kW cooling, 23.70 kW input, COP 2.73 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ185-4 (R404A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR404A compressor — 48.5 kW cooling, 18.42 kW input, COP 2.63 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland AFE13C4U-IAA (R290 hermetic recip, 60 Hz, LA) CatalogCompressorsCopelandR290 compressor — 0.36 kW cooling, 0.31 kW input, COP 1.16 at -30/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH485-7 (R454B scroll, 60 Hz, HT) CatalogCompressorsDanfossR454B compressor — 137.2 kW cooling, 40.43 kW input, COP 3.39 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland AFF12C1U-IAZ (R290 hermetic recip, 50 Hz, EF) CatalogCompressorsCopelandR290 compressor — 0.33 kW cooling, 0.23 kW input, COP 1.44 at -30/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRH051U5 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 12.8 kW cooling, 4.23 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ARE29C4E-IAI (R134A hermetic recip, 60 Hz, HT) CatalogCompressorsCopelandR134a compressor — 0.83 kW cooling, 0.41 kW input, COP 2.03 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss LLZ024T4A (R404A scroll, 50 Hz, LT) CatalogCompressorsDanfossR404A compressor — 5.8 kW cooling, 3.54 kW input, COP 1.63 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland ASE19C4E-IAA (R407C hermetic recip, 60 Hz, HT) CatalogCompressorsCopelandR407C compressor — 0.90 kW cooling, 0.48 kW input, COP 1.88 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ019T1C (R513A scroll, 60 Hz, MT) CatalogCompressorsDanfossR513A compressor — 5.6 kW cooling, 2.14 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ASM24C7U-IAI (R290 hermetic recip, 50 Hz, EM) CatalogCompressorsCopelandR290 compressor — 0.23 kW cooling, 0.17 kW input, COP 1.31 at -30/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ028-1 (R454A hermetic reciprocating, 60 Hz) CatalogCompressorsDanfossR454A compressor — 8.3 kW cooling, 3.31 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland CR21K6ME-TFM (R407C hermetic recip, 50 Hz, HT) CatalogCompressorsCopelandR407C compressor — 5.0 kW cooling, 1.61 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss PSH065A9 (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 82.6 kW cooling, 27.50 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland CS13K6E-TF5 (R404A hermetic recip, 60 Hz, EM) CatalogCompressorsCopelandR404A compressor — 1.7 kW cooling, 1.25 kW input, COP 1.34 at -25/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ185-4 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 43.1 kW cooling, 13.62 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland KCJ498HAG-SXH (R134A hermetic recip, 60 Hz, HT) CatalogCompressorsCopelandR134a compressor — 2.7 kW cooling, 1.12 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss DSH485-9 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 143.4 kW cooling, 43.25 kW input, COP 3.32 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland KCN463HAG-BXH (R134A hermetic recip, 50 Hz, HT) CatalogCompressorsCopelandR134a compressor — 1.5 kW cooling, 0.61 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
‹ Previous1…403404405406407…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet