Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 10,417–10,440 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss MLZ019T4B (R449A scroll, 50 Hz, MT) CatalogCompressorsDanfossR449A compressor — 7.1 kW cooling, 2.72 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZX29KCE-PFJ (R407F scroll, 50 Hz, MT) CatalogCompressorsCopelandR407F compressor — 5.2 kW cooling, 2.56 kW input, COP 2.02 at -15/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ032-3 (R454A hermetic reciprocating, 60 Hz) CatalogCompressorsDanfossR454A compressor — 9.1 kW cooling, 3.62 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 2DA8F23KE-TFD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 5.2 kW cooling, 3.21 kW input, COP 1.62 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T4B (R449A scroll, 60 Hz, MT) CatalogCompressorsDanfossR449A compressor — 8.5 kW cooling, 3.12 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DA8F28KE-TFD (R407C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407C compressor — 5.8 kW cooling, 3.62 kW input, COP 1.59 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ032-3 (R454C hermetic reciprocating, 60 Hz) CatalogCompressorsDanfossR454C compressor — 7.7 kW cooling, 3.00 kW input, COP 2.57 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DB3R12ML-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 42.5 kW cooling, 13.01 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ019T4B (R452A scroll, 50 Hz, MT) CatalogCompressorsDanfossR452A compressor — 6.8 kW cooling, 2.71 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DF3R15ML-TFD (R407F Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407F compressor — 23.4 kW cooling, 8.52 kW input, COP 2.75 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ032-3 (R455A hermetic reciprocating, 60 Hz) CatalogCompressorsDanfossR455A compressor — 8.4 kW cooling, 3.25 kW input, COP 2.57 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DS3R17ML-TFD (R407A Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR407A compressor — 23.0 kW cooling, 8.45 kW input, COP 2.72 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ019T4B (R452A scroll, 60 Hz, MT) CatalogCompressorsDanfossR452A compressor — 8.2 kW cooling, 3.22 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DANF47KL-TSK (R449A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR449A compressor — 11.6 kW cooling, 6.77 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ032-3 (R513A hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR513A compressor — 5.8 kW cooling, 2.30 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DAXF47KL-TSK (R513A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR513A compressor — 6.8 kW cooling, 4.43 kW input, COP 1.54 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T4B (R454C scroll, 50 Hz, MT) CatalogCompressorsDanfossR454C compressor — 6.5 kW cooling, 2.28 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DENF47KL-TSK (R449A Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR449A compressor — 9.6 kW cooling, 5.64 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ032-4 (R134a hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR134a compressor — 4.4 kW cooling, 1.75 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DENR18ML-TSK (R449A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR449A compressor — 31.0 kW cooling, 10.85 kW input, COP 2.86 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T4B (R454C scroll, 60 Hz, MT) CatalogCompressorsDanfossR454C compressor — 8.0 kW cooling, 2.68 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6DUNF13ML-AWD (R407C Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR407C compressor — 23.4 kW cooling, 14.04 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ032-4 (R134a hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 5.3 kW cooling, 2.10 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6DUNR49ME-TSE (R507 Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR507 compressor — 90.3 kW cooling, 36.23 kW input, COP 2.49 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…433434435436437…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one